LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Development and analytic validation of a sandwich ELISA for the measurement of α1-proteinase inhibitor concentrations in serum and feces of common marmosets (Callithrix jacchus).

Photo by natinati from unsplash

OBJECTIVE To develop and validate a sandwich ELISA for the measurement of α1-proteinase inhibitor (α1-PI) concentrations in serum and fecal samples obtained from common marmosets (Callithrix jacchus). SAMPLE Leftover serum… Click to show full abstract

OBJECTIVE To develop and validate a sandwich ELISA for the measurement of α1-proteinase inhibitor (α1-PI) concentrations in serum and fecal samples obtained from common marmosets (Callithrix jacchus). SAMPLE Leftover serum (n = 42) and fecal (23) samples submitted for diagnostic testing; paired serum and fecal samples obtained from 30 common marmosets at 2 research colonies. PROCEDURES A sandwich ELISA was developed and analytically validated by determining the lower limit of detection, linearity, accuracy, precision, and reproducibility. Reference intervals for α1-PI concentrations in serum and feces of common marmosets were calculated. RESULTS The standard curve was generated for concentrations between 1 and 100 ng/mL. Mean ± SD observed-to-expected ratio for serial dilutions of serum and fecal samples was 117.1 ± 5.6% (range, 112.2% to 123.0%) and 106.1 ± 19.7% (range, 82.6% to 130.2%), respectively. Mean observed-to-expected ratio for spiking recovery of serum and fecal samples was 102.9 ± 12.1% (range, 86.8% to 115.8%) and 97.9 ± 19.0% (range, 83.0% to 125.1%), respectively. Reference interval for serum concentrations of α1-PI was 1,254 to 1,813 μg/mL, for 3-day mean fecal concentrations was 11.5 to 42.2 μg/g of feces, and for 3-day maximum fecal concentrations was 13.2 to 51.2 μg/g of feces. CONCLUSIONS AND CLINICAL RELEVANCE The ELISA was linear, accurate, precise, and reproducible for quantification of α1-PI concentrations in serum and feces of common marmosets. However, the ELISA had limited linearity and accuracy for spiking recovery of fecal samples.

Keywords: serum fecal; common marmosets; serum feces; fecal samples; sandwich elisa; concentrations serum

Journal Title: American journal of veterinary research
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.