LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Effect of catheter diameter and injection rate of flush solution on renal contrast-enhanced ultrasonography with perfluorobutane in dogs.

Photo from wikipedia

OBJECTIVE To assess effects of catheter diameter and injection rate of flush solution (saline [0.9% NaCl] solution) on renal contrast-enhanced ultrasonography (CEUS) with perfluorobutane in dogs. ANIMALS 5 healthy Beagles.… Click to show full abstract

OBJECTIVE To assess effects of catheter diameter and injection rate of flush solution (saline [0.9% NaCl] solution) on renal contrast-enhanced ultrasonography (CEUS) with perfluorobutane in dogs. ANIMALS 5 healthy Beagles. PROCEDURES CEUS of the kidneys was performed by IV injection of contrast medium (0.0125 mL/kg) followed by injection of 5 mL of saline solution at rates of 1, 3, and 5 mL/s through a 20-gauge or 24-gauge catheter; thus, CEUS was repeated 3 times for each catheter diameter. Time-intensity curves were created for regions of interest drawn in the renal cortex and medulla. Repeatability was determined by calculating the coefficient of variation (CV). Statistical analysis was used to assess whether perfusion variables or CV of the perfusion variables was associated with catheter diameter or injection rate. RESULTS Perfusion variables did not differ significantly between catheter diameters. Time to peak enhancement (TTP) in the renal cortex was affected by injection rate, and there were significantly lower values for TTP at higher injection rates. The CEUS variables with the lowest CVs among injection rates were TTP for the renal cortex; the CV for TTP of the renal cortex was the lowest at an injection rate of 5 mL/s. CONCLUSIONS AND CLINICAL RELEVANCE Use of a 24-gauge catheter did not alter CEUS with perfluorobutane; therefore, such catheters could be used for CEUS of the kidneys of small dogs. Moreover, a rate of 5 mL/s is recommended for injection of flush solution to obtain greater accuracy for renal CEUS in Beagles.

Keywords: catheter diameter; solution; rate; injection; injection rate

Journal Title: American journal of veterinary research
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.