We report the case of a 72-year old man previously treated with an aortic endograft for an abdominal aortic aneurysm. After 3 years the patient developed a sepsis. Imaging and… Click to show full abstract
We report the case of a 72-year old man previously treated with an aortic endograft for an abdominal aortic aneurysm. After 3 years the patient developed a sepsis. Imaging and blood exams detected an endograft infection related to Listeria monocytogenes. Patients underwent endograft removal and in-situ aortic reconstruction with a cryopreserved allograft. A continuous antibacterial therapy has been established. One-month follow-up revealed the absence of clinically relevant infection with patency of the graft and absence of biochemical inflammatory markers.
               