2.6 Validation of the Measurement of Aortic Stiffness by the CARDIS Laser Doppler Vibrometer

Photo by nci from unsplash

Purpose: There is a need for new tools to screen large populations for cardiovascular disease risk. The CARDIS consortium (European Union H2020 funding) developed an easy-to-use, non-contact device for measuring… Click to show full abstract

Purpose: There is a need for new tools to screen large populations for cardiovascular disease risk. The CARDIS consortium (European Union H2020 funding) developed an easy-to-use, non-contact device for measuring carotid to femoral pulse wave velocity (cfPWV). It consists in a laser doppler vibrometer (LDV), which measures skin vibrations induced by large artery pulses. Pulse waveforms can be tracked and transit time (TT) can be calculated. This study aimed at comparing LDV-cfPWV with the reference cfPWV measured by applanation tonometry (Sphygmocor). Methods: We included 100 patients with mild to stage 3 hypertension, controlled or not. Reflective tapes were applied on the carotid and femoral arteries to measure LDV-cfPWV 4 times. TT was measured by the foot-to-foot method from the maximum of 2nd derivative using in-house algorithms not requiring ECG, and compared to Sphygmocor (3 acquisitions). Results: LDV-cfPWV was obtained in 100% of patients. Mean age was 47 ± 19 (range 19–85). Hypertensives were well controlled (119/65 mmHg). Mean value of LDV-cfPWV was 6.9 ± 1.7 m/s, compared to 7.5 ± 1.7 m/s with Sphygmocor, bias 0.65 ± 1.27, R value 0.72 (Figure 1), which qualifies agreement as acceptable according to the guidelines from the ARTERY Society [1]. Reproducibility was good with a median coefficient of variation of 5.6%. LDV-cfPWV showed similar associations with age and blood pressure than tonometry (r = 0.68, p < 0.001 and r = 0.44, p < 0.001, respectively). Conclusion: Non-contact measurement of pulse wave velocity by laser doppler vibrometry is feasible, fast and easy to perform, and provides acceptable agreement with reference technique. Association between cfPWV measured by LDV and by Sphygmocor (reference technique) R = 0.72 p < 0.001 LD Vcf PW V (m /s ) Sphygmocor-cfPWV (m/s) 14 12 10

Keywords: doppler vibrometer; laser doppler; cfpwv; ldv cfpwv

Journal Title: Artery Research
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.