LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Minimally Invasive Augmented Fixation for Anatomical Reduction of Grade 2 and Grade 3 Listhesis in Patients with Osteoporosis

Photo by polarmermaid from unsplash

Study Design A retrospective study. Purpose To study the efficacy of augmented fixation for anatomical reduction of grade 2 and grade 3 listhesis in patients with osteoporosis. Overview of Literature… Click to show full abstract

Study Design A retrospective study. Purpose To study the efficacy of augmented fixation for anatomical reduction of grade 2 and grade 3 listhesis in patients with osteoporosis. Overview of Literature Spondylolisthesis in osteoporotic patients requiring spinal fixation are associated with complications such as loss of surgical construct stability, screw pulling out, and screw loosening. Augmented fixation is a novel strategy to achieve necessary construct integrity. Methods Thirteen consecutive patients with grade 2 or grade 3 listhesis, with proven osteoporosis on dual energy X-ray absorptiometry (DEXA) scan, and who underwent augmented fixation for reduction of listhesis were retrospectively analyzed. In all patients, surgical access was achieved with a fixed 22 mm tubular retractor. A modified technique of bilateral, sequential, transforaminal decompression and discectomy, followed by reduction of listhesis using unilaterally placed augmented screws was employed in all the cases. Patients were followed up with plain X-rays at regular intervals to assess for implant stability and fusion status. All patients were started on medical treatment for osteoporosis. Results The mean age of the patients was 52.46 years, with 12 females and one male. The median T-score on DEXA scan was −3.0. Of the 13 patients, listhesis was at L4–L5 in five and at L5–S1 in eight. Nine patients had grade 2 listhesis, while four patients had grade 3 listhesis. Complete reduction was achieved in 10 patients. The median duration of follow-up was 18 months. Postoperative outcomes were satisfactory in all cases. Conclusions Augmented fixation is a useful technique for achieving anatomical reduction of listhesis in patients with osteoporosis.

Keywords: fixation; listhesis; anatomical reduction; grade listhesis; augmented fixation

Journal Title: Asian Spine Journal
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.