LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

Photo from wikipedia

Objective To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in… Click to show full abstract

Objective To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20–99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6–91.7%), 92.5% (95% CI, 91.9–93.1%), 86.5% (95% CI, 85.0–87.9%), 99.2% (95% CI, 99.0–99.4%), and 84.3% (95% CI, 82.7–85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3–9.4%). The independent risk factors for diagnostic failures were lesions ≤ 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23–2.81), lesion size 1.1–2 cm (1.75; 1.45–2.11), subsolid lesions (1.81; 1.32–2.49), use of fine needle aspiration only (2.43; 1.80–3.28), final diagnosis of benign lesions (2.18; 1.84–2.58), and final diagnosis of lymphomas (10.66; 6.21–18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13–0.75) and conventional CT-guidance (0.55; 0.32–0.94) reduced diagnostic failures. Conclusion The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.

Keywords: needle lung; diagnostic accuracy; accuracy; transthoracic needle; percutaneous transthoracic; accuracy percutaneous

Journal Title: Korean Journal of Radiology
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.