LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Hemoclot Thrombin Inhibitor Assay and Expected Peak-Trough Levels of Dabigatran: A Multicenter Study

Photo by clevertrevor from unsplash

Purpose Dabigatran concentrations monitoring are gaining importance of special situations, but limited data are available for the expected peak and trough levels. The hemoclot thrombin inhibitor (HTI) is dabigatran-calibrated quantitative… Click to show full abstract

Purpose Dabigatran concentrations monitoring are gaining importance of special situations, but limited data are available for the expected peak and trough levels. The hemoclot thrombin inhibitor (HTI) is dabigatran-calibrated quantitative determination of dabigatran concentration. This study aims to validate HTI assay as the quantification choice of dabigatran, and providing the expected peak and trough levels. Materials and Methods This is a multi-center methodology validate study, including seven hospitals from Beijing, Shanghai, Henan, Hunan, Chongqing, and Fujian. We retrospectively analyzed plasma samples taken from 118 healthy subjects and 183 patients receiving dabigatran. Dabigatran concentrations were measured with HTI assay and high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Linear regression, Spearman correlation and Bland-Altman analysis were used in this study. Results The mean concentration ratio of HPLC-MS/MS and HTI assays was 1.03 and 0.98 at 2 and 12 h, and the acceptance ranges for both the ratio limit as well as the limit of agreement were met, suggesting good agreement between the HTI-derived plasma concentrations and HPLC-MS/MS. The reference detection range of single dose dabigatran 150 mg in healthy subjects was 33–159 ng/ml. About 500 blood samples were taken from 183 patients suggested that the expected peak and trough levels range of dabigatran 110 mg was about 95–196 and 36–92 ng/ml. Conclusion Hemoclot thrombin inhibitor assay can be a good quantitative detection method of dabigatran. Expected peak and trough levels provide a basis for the rational use of dabigatran, and provide important Asian population data for the update of the international clinical guidelines for hematological testing. Clinical Trial Registration [https://clinicaltrials.gov], identifier [NCT03161496].

Keywords: trough levels; dabigatran; peak trough; expected peak; study

Journal Title: Frontiers in Cardiovascular Medicine
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.