Reinforced masonry constructions and their elements must meet strength and stability requirements. These conditions determine wall structure safety during construction and operation. Safety depends on diagnostically aimed tests that check… Click to show full abstract
Reinforced masonry constructions and their elements must meet strength and stability requirements. These conditions determine wall structure safety during construction and operation. Safety depends on diagnostically aimed tests that check the objects’ quality or locate damages to structural elements that arise during operation. This article is focused on the experimental modal analysis research of reinforcement ceramic masonry elements. The aim of the research was to check whether it is possible to observe the damage in reinforced masonry structures and the accompanying vibration of signal transition functions by conducting pilot studies and using different types of reinforcements. The experiment was conducted on three samples of various types of reinforced brick walls. During the vibration tests, the segments were subjected to various loads, and it was observed how the increasing cracks and damage changed the courses of the measured functions of the vibration process, reflecting the damage to the segments. This made it possible to assess the variability of the vibration characteristics of the tested reinforced wall elements and the usefulness of the applied test method. The aim of the study was to check the assessed effectiveness by testing the degradation of the reinforced wall elements. The research confirmed the usefulness of the SISO methodology in identifying damages, which has been implemented in selected precast factories in Poland.
               