LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Humidity Control for Front Opening Unified Pod after Opening Its Door in a Mini-Environment

Photo from wikipedia

Wafers are usually placed in a front opening unified pod (FOUP) while waiting in the line of manufacturing processes; a conventional way for preventing (or removing) contamination is to purge… Click to show full abstract

Wafers are usually placed in a front opening unified pod (FOUP) while waiting in the line of manufacturing processes; a conventional way for preventing (or removing) contamination is to purge an FOUP with a gas, so as to maintain the cleanliness level. This study investigates the effect of the flow rate of clean dry air (CDA), supplied to the purge system and air curtain, on the moisture prevention performance, while opening the FOUP door in a mini-environment. An initial relative humidity (RH) in the pre-purged FOUP was approximately 0%, whereas an RH in the mini-environment was about 43%. Conventional, diffuser, and panel purge approaches were tested. The results showed that the moisture in the surroundings rapidly entered the FOUP when the door was opened, without using either the purge system or air curtain. When the CDA was then supplied to both the purge system and the air curtain, the RH values decreased significantly; the drop slope of the RH for the diffuserand panel-purge processes was much larger than that of the conventional-purge process. In addition, the moisture prevention performance when the developed panel-purge system was used was slightly lower than when using the diffuser-purge system. However, the use of the panel-purge method could sufficiently suppress the vibration problem. In the present study, the case with CDA flow rates of 150 L/min to the air curtain and 250 L/min to the panel-purge device had the best moisture prevention performance, because of the smallest values for both the mean and maximum RH values (i.e., 1.3% and 9.5%, respectively) in the FOUP.

Keywords: panel purge; air; mini environment; purge; purge system

Journal Title: Applied Sciences
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.