The aim of this study was to propose a finite element method based numerical approach for evaluating various hallux valgus treatment strategies. We developed three-dimensional hallux valgus deformity models, with… Click to show full abstract
The aim of this study was to propose a finite element method based numerical approach for evaluating various hallux valgus treatment strategies. We developed three-dimensional hallux valgus deformity models, with different metatarsal osteotomy methods and Kirschner wire fixation strategies, under two types of standing postures. Ten Kirschner wire fixations were analyzed and compared. The fixation stability, bone stress, implant stress, and contact pressure on the osteotomy surface were calculated as the biomechanical indexes. The results showed that the biomechanical indexes of the osteotomy and Kirschner wire fixations for hallux valgus deformity could be effectively analyzed and fairly evaluated. The distal metatarsal osteotomy method provided better biomechanical indexes compared to the proximal metatarsal osteotomy method. This study proposed a finite element method based numerical approach for evaluating various osteotomy and Kirschner wire fixations for hallux valgus deformity before surgery.
               
Click one of the above tabs to view related content.