It is a key challenge to continuously power personal wearable health monitoring systems. This paper reports a novel liquid metal-enhanced wearable thermoelectric generator (LM-WTEG that directly converts body heat into… Click to show full abstract
It is a key challenge to continuously power personal wearable health monitoring systems. This paper reports a novel liquid metal-enhanced wearable thermoelectric generator (LM-WTEG that directly converts body heat into electricity for powering the wearable sensor system. The gallium-based liquid metal alloys with room-temperature melting point (24~30 °C) and high latent heat density (about 500 MJ/m3) are used to design a new flexible finned heat sink, which not only absorbs the heat through the solid-liquid phase change of the LM and enhances the heat release to the ambient air due to its high thermal conduction. The LM finned is integrated with WTEG to present high biaxial flexibility, which could be tightly in contact with the skin. The LM-WTEG could achieve a super high output power density of 275 μW/cm2 for the simulated heat source (37 °C) with the natural convective heat transfer condition. The energy management unit, the multi-parameter sensors (including temperature, humidity, and accelerometer), and Bluetooth module with a total energy consumption of about 65 μW are designed, which are fully powered from LM-WTEG through harvesting body heat.
               