LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Colostrum Quality Assessment in Dairy Goats: Use of an On-Farm Optical Refractometer

Photo by lucastodes from unsplash

Simple Summary Newborn goat kids need to consume high-quality colostrum in the first hours after birth to ensure adequate transfer of passive immunity, through the absorption of immunoglobulins. However, some… Click to show full abstract

Simple Summary Newborn goat kids need to consume high-quality colostrum in the first hours after birth to ensure adequate transfer of passive immunity, through the absorption of immunoglobulins. However, some goats fail to produce high-quality colostrum, and tools for on-farm assessment of colostrum quality are needed. This work evaluated the quality of colostrum in Malagueña dairy goats, through measurement of immunoglobulin G (IgG), fat and protein concentrations in colostrum during the first 3 days after parturition. A handheld optical Brix refractometer, an instrument that is easy to use on the farm, was evaluated for accuracy to estimate colostrum quality. The optical Brix refractometer was found to be suitable for on-farm use to estimate the IgG content in the goat colostrum. Abstract Failure of passive immunity transfer is one of the main causes of increased susceptibility to infectious agents in newborn kids. To ensure successful transfer of passive immunity, kids need to be fed high-quality colostrum, containing an adequate concentration of IgG. This work evaluated the quality of colostrum obtained in the first 3 days postpartum from Malagueña dairy goats. The IgG concentration in colostrum was measured using an ELISA as a reference method, and it was estimated by optical refractometer. Colostrum composition in terms of fat and protein was also determined. The mean concentration of IgG was 36.6 ± 2.3 mg/mL, 22.4 ± 1.5 mg/mL and 8.4 ± 1.0 mg/mL on days 1, 2 and 3 after parturition, respectively. Brix values obtained using the optical refractometer were 23.2%, 18.6% and 14.1% for days 1, 2 and 3, respectively. In this population, 89% of goats produced high-quality colostrum with IgG concentrations of >20 mg/mL on the day of parturition, but this percentage declined dramatically over the following 2 days. The quality of the fresh colostrum estimated with the optical refractometer was positively correlated with those obtained using ELISA (r = 0.607, p = 0.001). This study highlights the importance of feeding first-day colostrum to newborn kids and demonstrates that the optical Brix refractometer is suitable for the on-farm estimation of IgG content in colostrum.

Keywords: quality colostrum; optical refractometer; colostrum; quality; colostrum quality

Journal Title: Biology
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.