LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Design and Engineering of a Palm-Sized Optical Immunosensing Device for the Detection of a Kidney Dysfunction Biomarker

Photo from wikipedia

Creatinine is one of the most common and specific biomarkers for renal diseases, usually found in the serum and urine of humans. Its level is extremely important and critical to… Click to show full abstract

Creatinine is one of the most common and specific biomarkers for renal diseases, usually found in the serum and urine of humans. Its level is extremely important and critical to know, not only in the case of renal diseases, but also for various other pathological conditions. Hence, detecting creatinine in clinically relevant ranges in a simplistic and personalized manner is interesting and important. In this direction, an optical sensing device has been developed for the simple, point-of-care detection of creatinine. The developed biosensor was able to detect creatinine quantitatively based on optical signals measured through a change in color. The sensor has been integrated with a smartphone to develop a palm-sized device for creatinine analysis in personalized settings. The sensor has been developed following facile chemical modification steps to anchor the creatinine-selective antibody to generate a sensing probe. The fabricated sensor has been thoroughly characterized by FTIR, AFM, and controlled optical analyses. The quantitative analysis is mediated through the reaction between picric acid and creatinine which was detected by the antibody-functionalized sensor probe. The differences in color intensity and creatinine concentrations show an excellent dose-dependent correlation in two different dynamic ranges from 5 to 20 μM and 35 to 400 μM, with a detection limit of 15.37 (±0.79) nM. Several interfering molecules, such as albumin, glucose, ascorbic acid, citric acid, glycine, uric acid, Na+, K+, and Cl−, were tested using the biosensor, in which no cross-reactivity was observed. The utility of the developed system to quantify creatinine in spiked serum samples was validated and the obtained percentage recoveries were found within the range of 89.71–97.30%. The fabricated biosensor was found to be highly reproducible and stable, and it retains its original signal for up to 28 days.

Keywords: palm sized; acid; detection; creatinine; device; sensor

Journal Title: Biosensors
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.