The New Zealand Building Code contains minimum durability requirements for components. For roof structures the requirement is 50 years if the component is structural or 15 years if it is… Click to show full abstract
The New Zealand Building Code contains minimum durability requirements for components. For roof structures the requirement is 50 years if the component is structural or 15 years if it is not. Metal roof claddings are very common in New Zealand, and roof spaces are typically not deliberately ventilated. Recently, a number of roofs are failing to meet their durability requirement, and the lack of deliberate ventilation is a contributory factor in some cases. In this paper, we consider roof failures and analyse them using the hygrothermal simulation software WUFI® 2D (version 4.1). Using the National Research Council of Canada’s Guideline on Design for Durability of Building Envelopes, we evaluate to what extent the guideline can be used for such more complex models. Experimental data from a residential dwelling where excessive roof moisture issues were discovered shortly after occupancy are presented. A novel remedial solution using daytime-only ventilation to the roof cavity was trialled, and the data were used to benchmark a two-dimensional numerical simulation of the roof space using WUFI® 2D. A larger hygrothermal data set for 71 dwellings is presented together with relevant climatic conditions. The study works towards evidence-based building code changes for roof ventilation and is an example of using the guideline document for more complicated building envelope assemblies.
               