Simple Summary Advances in screening methods and new therapeutic strategies have lead to a continuous decline in cancer death rates, especially over the last ten years. As a consequence, the… Click to show full abstract
Simple Summary Advances in screening methods and new therapeutic strategies have lead to a continuous decline in cancer death rates, especially over the last ten years. As a consequence, the number of patients with spinal metastases is increasing. In modern oncological treatment surgery followed by postoperative radiotherapy for spinal metastases has gained a decisive role. For spinal stabilization, pedicle screws and rods are used. They used to be made of titanium or cobalt–chrome alloys. Recently, carbon-fiber-reinforced (CFR) polyethyl-ether-ether-ketone (PEEK) was introduced as a new material reducing artifacts on imaging and showing less perturbation effects on photon radiation. The aim of this study is to report on the safety and efficacy of CFR-PEEK pedicle screw systems for spinal neoplasms in a large cohort of consecutive patients. We could show that implant-related complications, such as intraoperative screw breakage and screw loosening, were rare. So, we conclude that CFR-PEEK is a safe and efficient alternative to titanium for oncological spinal instrumentation. Abstract (1) Background: Surgery for spinal metastases has gained a decisive role in modern oncological treatment. Recently, carbon-fiber-reinforced (CFR) polyethyl-ether-ether-ketone (PEEK) pedicle screw systems were introduced, reducing artifacts on imaging and showing less perturbation effects on photon radiation. Preliminary clinical experience with CFR-PEEK implants for spinal metastases exists. The aim of this monocentric study is to report on the safety and efficacy of CFR-PEEK pedicle screw systems for spinal neoplasms in a large cohort of consecutive patients. (2) Methods: We retrospectively analyzed prospectively the collected data of consecutive patients being operated on from 1 August 2015 to 31 October 2021 using a CFR-PEEK pedicle screw system for posterior stabilization because of spinal metastases or primary bone tumors of the spine. (3) Results: We included 321 patients of a mean age of 65 ± 13 years. On average, 5 ± 2 levels were instrumented. Anterior reconstruction was performed in 121 (37.7%) patients. Intraoperative complications were documented in 30 (9.3%) patients. Revision surgery for postoperative complications was necessary in 55 (17.1%) patients. Implant-related complications, such as intraoperative screw breakage (3.4%) and screw loosening (2.2%), were rare. (4) Conclusions: CFR-PEEK is a safe and efficient alternative to titanium for oncological spinal instrumentation, with low complication and revision rates in routine use and with the advantage of its radiolucency.
               
Click one of the above tabs to view related content.