Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography

Photo by nickkarvounis from unsplash

This study aims to investigate differences in the mean corneal power of annular zones (corneal power measured over the inner annular zone of difference diameters) and rings (corneal power measured… Click to show full abstract

This study aims to investigate differences in the mean corneal power of annular zones (corneal power measured over the inner annular zone of difference diameters) and rings (corneal power measured over a ring of different diameters) centered on the corneal apex using the swept-source optical coherence tomography technique. The mean anterior axial curvature (AAC), posterior axial curvature (PAC), and total corneal power (TCP) centered on the corneal apex with the annular rings (0–2 mm, 2–4 mm, 4–6 mm, and 6–8 mm) and zones were assessed using the ANTERION device. The paired-sample t-test was used for data comparison. For the 0–2 mm comparison, the AAC, PAC, and TCP values of rings and zones were interchangeable. For the 2–4 mm comparison, the AAC of the rings was lower than that of the zones (p = 0.004), and the TCP values of the rings were higher than that of the zones (p < 0.001). For the 4–6 mm comparison, the AAC of the rings was lower than that of the zones (p < 0.001), and the PAC and TCP values of the rings were higher than that of the zones (both p < 0.001). For the 6–8 mm comparison, the AAC of the rings was lower than that of the zones (p < 0.001), and the PAC and TCP values of the rings were higher than that of the zones (both p < 0.001). Comparisons between AAC and TCP in each sub-region showed significant differences both in the rings (p < 0.001) and the zones (p < 0.008). Differences in the AAC, PAC, and TCP measured at different diameters (2–4 mm, 4–6 mm, and 6–8 mm) of the rings and zones, centered on the corneal apex, should be noticed in clinical practice. As the diameter increases, the difference between the rings and the zones in terms of AAC, PAC, and TCP increase as well. Clinicians should also pay attention to differences between AAC and TCP for the rings and the zones within the same annular region.

Keywords: pac tcp; rings zones; corneal power; comparison

Journal Title: Diagnostics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.