LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Undersampled Diffusion-Weighted 129Xe MRI Morphometry of Airspace Enlargement: Feasibility in Chronic Obstructive Pulmonary Disease

Photo from wikipedia

Multi-b diffusion-weighted hyperpolarized gas MRI measures pulmonary airspace enlargement using apparent diffusion coefficients (ADC) and mean linear intercepts (Lm). Rapid single-breath acquisitions may facilitate clinical translation, and, hence, we aimed… Click to show full abstract

Multi-b diffusion-weighted hyperpolarized gas MRI measures pulmonary airspace enlargement using apparent diffusion coefficients (ADC) and mean linear intercepts (Lm). Rapid single-breath acquisitions may facilitate clinical translation, and, hence, we aimed to develop single-breath three-dimensional multi-b diffusion-weighted 129Xe MRI using k-space undersampling. We evaluated multi-b (0, 12, 20, 30 s/cm2) diffusion-weighted 129Xe ADC/morphometry estimates using a fully sampled and retrospectively undersampled k-space with two acceleration-factors (AF = 2 and 3) in never-smokers and ex-smokers with chronic obstructive pulmonary disease (COPD) or alpha-one anti-trypsin deficiency (AATD). For the three sampling cases, mean ADC/Lm values were not significantly different (all p > 0.5); ADC/Lm values were significantly different for the COPD subgroup (0.08 cm2s−1/580 µm, AF = 3; all p < 0.001) as compared to never-smokers (0.05 cm2s−1/300 µm, AF = 3). For never-smokers, mean differences of 7%/7% and 10%/7% were observed between fully sampled and retrospectively undersampled (AF = 2/AF = 3) ADC and Lm values, respectively. For the COPD subgroup, mean differences of 3%/4% and 11%/10% were observed between fully sampled and retrospectively undersampled (AF = 2/AF = 3) ADC and Lm, respectively. There was no relationship between acceleration factor with ADC or Lm (p = 0.9); voxel-wise ADC/Lm measured using AF = 2 and AF = 3 were significantly and strongly related to fully-sampled values (all p < 0.0001). Multi-b diffusion-weighted 129Xe MRI is feasible using two different acceleration methods to measure pulmonary airspace enlargement using Lm and ADC in COPD participants and never-smokers.

Keywords: 129xe mri; diffusion; diffusion weighted; adc; weighted 129xe; airspace enlargement

Journal Title: Diagnostics
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.