Compared to traditional ultrasonic detection methods, the electromagnetic acoustic transducer (EMAT) technique can be applied in many hostile environments such as elevated temperatures, on-line inspections, etc. However, the EMAT technique has a low conversion efficiency. This paper develops a numerical model to study the effects of the coil configurations on the conversion efficiency of shear-wave EMAT on 7050 aluminum alloy. The numerical model is fully validated by the experiment data. The effects of the configuration parameters, including the coil wires’ cross-sectional area, coil wires’ cross-sectional shape, and distance between coil wires, on the conversion efficiency are then discussed. The results indicate that after using the coil with a square cross-section, the conversion efficiency of EMAT is increased by 22.5%. In addition, the coil wires’ cross-sectional area and the distance between coil wires also have a significant effect on the conversion efficiency.
               