A Comprehensive Evaluation of Different Power Quantities in DC Electric Arc Furnace Power Supplies

Photo from wikipedia

Conventionally, DC arc furnaces are fed by thyristor rectifiers to control the level of current or power transferred to the load. With the advancement of high-power transistors, other structures such… Click to show full abstract

Conventionally, DC arc furnaces are fed by thyristor rectifiers to control the level of current or power transferred to the load. With the advancement of high-power transistors, other structures such as diode rectifiers and DC choppers have been introduced and developed for the feeding system of DC electric arc furnaces. In this paper, the effect of different power supply systems on power quality indexes is discussed. In this regard, two types of feeding systems are considered, including a power supply system based on thyristor rectifiers and a power supply system based on diode rectifiers and DC choppers. In addition, different control methods, including constant current control (CCC) and constant power control (CPC), on DC electric arc furnaces are applied. For evaluating the power quality indexes, voltage and current harmonic distortion, unbalance of voltage and current, and power factor on the AC side are investigated for different power supply systems. Simulation results were performed with PSCAD/EMTDC software. It is shown that the power supply systems with diode rectifiers and DC choppers have superiority in comparison to the types based on thyristor rectifiers. According to the results, the average current THD is reduced from 16.55% in the thyristor rectifier to 8.40% in the chopper rectifiers with the CCC method and from 19.27% in the thyristor rectifier to 7.38% in the chopper rectifiers with the CPC method. Moreover, the average voltage THD is reduced from 5.67% in the thyristor rectifier to 3.02% in the chopper rectifiers with the CCC method. The result is similar to the CPC method. Furthermore, for a specific power supply system, the harmonic distortion is lower in the case of the CPC method than in the CCC method.

Keywords: different power; power supply; power; electric arc; thyristor

Journal Title: Energies
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.