LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Biological Monitoring of Occupational Exposure to Metals in Electric Steel Foundry Workers and Its Contribution to 8-Oxo-7,8-Dihydro-2′-Deoxyguanosine Levels

Photo from wikipedia

In this study, the urinary concentrations of selected metals in workers from an electric steel foundry in Tunisia were assessed and compared with existing biological limit values and general population… Click to show full abstract

In this study, the urinary concentrations of selected metals in workers from an electric steel foundry in Tunisia were assessed and compared with existing biological limit values and general population reference values. Moreover, the association between oxidative DNA damage, measured as urinary 8-oxo-7,8-dihydro-2’deoxyguanosine (8-oxodG) and co-exposure to metals and polycyclic aromatic hydrocarbons (PAHs) was evaluated. Urinary levels of 12 metals were determined by inductively coupled plasma-mass spectrometry (ICP-MS) in end-shift spot samples from 89 workers. The urinary levels of phenanthrene (U-PHE), as marker of exposure to PAHs, and 8-oxodG were also available. Median levels ranged from 0.4 µg/L (cobalt, Co, and thallium, Tl) to 895 µg/L (zinc, Zn). Only 1% of samples was above the biological limit values for Co, and up to 13.5% of samples were above limit values for Cd. From 3.4% (Co) to 72% (lead, Pb) of samples were above the reference values for the general population. Multiple linear regression models, showed that manganese (Mn), Zn, arsenic (As), barium (Ba), Tl, and Pb were significant predictors of 8-oxodG (0.012 ≤ p ≤ 0.048); U-PHE was also a significant predictor (0.003 ≤ p ≤ 0.059). The variance explained by models was low (0.11 ≤ R2 ≤ 0.17, p < 0.005), showing that metals and PAHs were minor contributors to 8-oxodG. Overall, the comparison with biological limit values showed that the study subjects were occupationally exposed to metals, with levels exceeding biological limit values only for Cd.

Keywords: limit; electric steel; exposure; biological limit; steel foundry; limit values

Journal Title: International Journal of Environmental Research and Public Health
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.