LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Risk-Based Assessment of 132 kV Electric Distribution Substations and Proximal Residential Areas in the Mangaung Metropolitan Region

Photo from wikipedia

Annually, an estimate of 2.3 million workers die prematurely due to occupational injuries and illnesses. In this study, a risk assessment was conducted to evaluate the compliance of 132 kV… Click to show full abstract

Annually, an estimate of 2.3 million workers die prematurely due to occupational injuries and illnesses. In this study, a risk assessment was conducted to evaluate the compliance of 132 kV electric distribution substations and proximal residential areas with the South African occupational health and safety Act 85 of 1993. Data were collected from 30 electric distribution substations and 30 proximal residential areas using a checklist. Distribution substations of 132 kV were assigned an overall compliance value of ≥80%, while a composite risk value of < 0.5 was assigned to individual residential areas. The Shapiro–Wilk test was used to check for data normality before multiple comparisons and the Bonferroni adjustment was applied. Non-compliances in electric distribution substations were as a result of poor housekeeping and inappropriate fencing conditions. Ninety-three percent of the electric distribution substations (28/30) scored < 75% compliance on housekeeping and 30% (7/30) were non-compliant (<100%) on fencing. Conversely, there was compliance in the proximal residential areas concerning the substations. Statistically significant differences were found when substation positioning and surrounding infrastructure (p < 0.00), electromagnetic field sources (p < 0.00) and maintenance/general tidiness (p < 0.00) were compared. A peak risk value of 0.6 was observed when comparing the substation positioning with proximal electromagnetic field sources in the residential area. Housekeeping and fencing in the distribution substations must be improved to prevent occupational incidents such as injuries, fire outbreaks, theft and vandalism.

Keywords: electric distribution; residential areas; risk; proximal residential; distribution; distribution substations

Journal Title: International Journal of Environmental Research and Public Health
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.