(1) Background: The adjustable transobturator male system (ATOMS) device serves to treat post-prostatectomy incontinence, as it enhances residual urinary sphincteric function by dorsal compression of the bulbar urethra. We investigated… Click to show full abstract
(1) Background: The adjustable transobturator male system (ATOMS) device serves to treat post-prostatectomy incontinence, as it enhances residual urinary sphincteric function by dorsal compression of the bulbar urethra. We investigated the clinical parameters affecting continence recovery using this device and developed a decision aid to predict success. (2) Methods: We reviewed consecutive men treated with first-time ATOMS for post-prostatectomy incontinence from 2014 to 2021 at our institution. Patient demographics, reported pads per day (PPD), 24-h pad-test and Standing Cough Test (SCT), results’ grades 1–4, according to Male Stress Incontinence Grading Scale (MSIGS), and the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) questionnaire were assessed. Treatment success was defined as no pads or a single PPD with ≤20-mL 24-h pad-test. Logistic regression was performed using a stepwise model (entry 0.15 and stay criterium 0.1) to evaluate independent variables’ determinant of dryness. Receiver-operating characteristic (ROC) curves for predictive variables were evaluated and their area under curve (AUC) was compared. A nomogram was generated and internally validated to predict probability of treatment success. (3) Results: Overall, 149 men (median age 70 years, IQR 7) were evaluated with a median follow-up of 45 months (IQR 26). Twelve patients (8%) had previous devices for incontinence, and 21 (14.1%) had pelvic radiation. Thirty-five men (23.5%) did not achieve continence after ATOMS adjustment (use of no or one security PPD with ≤20-mL 24-h pad-test). In univariate analysis, Charlson comorbidity index (p = 0.0412), previous urethroplasty (p = 0.0187), baseline PPD (p < 0.0001), 24-h pad-test (p < 0.0001), MSIGS (p < 0.0001), and ICIQ-SF questionnaire score (p < 0.0001) predicted ATOMS failure. In a multivariable model, 24-h pad-test (p = 0.0031), MSIGS (p = 0.0244), and radiotherapy (p = 0.0216) were independent variables, with AUC 0.8221. The association of MSIGS and 24-h pad-test was the superior combination (AUC 0.8236). A nomogram to predict the probability of ATOMS failure using the independent variables identified was proposed. (4) Conclusions: Several variables were identified as predictive of success for ATOMS using clinical history, physical examination (MSIGS), and factors that evaluate urine loss severity (PPD, 24-h pad-test, and ICIQ-SF questionnaire). MSIGS adds prognostic value to 24-h pad-test in assessing success of ATOMS device to treat post-prostatectomy incontinence. A nomogram was proposed to calculate the risk of ATOMS failure, which could be of interest to personalize the decision to use this device or not in the individual patient.
               
Click one of the above tabs to view related content.