A magnesium phosphate cement-based engineered cementitious composite (MPC-ECC) was developed using polyvinyl alcohol (PVA) fibers and fly ash. In this study, the bond behavior of MPC-ECC with ordinary concrete was… Click to show full abstract
A magnesium phosphate cement-based engineered cementitious composite (MPC-ECC) was developed using polyvinyl alcohol (PVA) fibers and fly ash. In this study, the bond behavior of MPC-ECC with ordinary concrete was evaluated through single and double shear bond strength tests. The effects of the water to solid mass ratio (W/S), the sand to binder mass ratio (S/B), the molar ratio of MgO to KH2PO4 (M/P), the fly ash content (F), the borax dosage (B), the volume fraction of PVA fibers (Vf), and curing age on the bond behavior of MPC-ECC with ordinary concrete were examined. The results showed that as the W/S increased, the single and double shear bond strengths were gradually reduced. As the S/B increased, the double shear bond strength increased; the single shear bond strength first decreased up to an S/B of 0.1 and then increased. With the increase of M/P, the single and double shear bond strengths increased. With the increase of F, the single shear bond strength first increased up to an F of 30% and then decreased; the double shear bond strength decreased. With the increase of B, the single and double shear bond strengths increased first and then decreased, and their strength reached its maximum at a B of 6%. The increase of Vf improved the single and double shear bond strengths. The research results can provide some technical guidance for repairing concrete structures with MPC-ECC.
               