To meet the requirement of lighter weight and better performance in tube hydroforming, one of the most important tasks is to accurately predict the forming limit of thin-walled tubes under… Click to show full abstract
To meet the requirement of lighter weight and better performance in tube hydroforming, one of the most important tasks is to accurately predict the forming limit of thin-walled tubes under nonlinear loading paths. This work established the M-K+DF2012 model, a combination of the M-K model and the DF2012 ductile fracture criterion, for the forming limit prediction of thin-walled tubes under nonlinear loading paths. In this model, the failure of the groove is determined by the DF2012 criterion, and the corresponding strains in the uniform region are the limit strains. The limit strains of an AA6061 aluminum alloy tube under a set of linear loading paths and two typical nonlinear loading paths were tested. Parameter values of the M-K+DF2012 model for the tube were determined based on the experimental limit strains under linear loading paths, and the limit strains under the two nonlinear loading paths were predicted. Then the strain-based forming limit diagram (ε-FLD) and the polar effective plastic strain FLD (PEPS-FLD) of the tube under different pre-strains were predicted and discussed. The results show that the limit strains of the tube are obviously path-dependent, and the M-K+DF2012 model can reasonably capture the limit strains of the tube under both linear and nonlinear loading paths. The predicted ε-FLD shows a strong dependence on the pre-strain, while the predicted PEPS-FLD is weakly strain path-dependent and almost path-independent on the right-hand side for the AA6061 tube.
               