This article describes a new technique for the preparation of hollow fiber (HF) membrane samples using an automatic manipulator unit. The manipulator uses a syringe needle to form a HF… Click to show full abstract
This article describes a new technique for the preparation of hollow fiber (HF) membrane samples using an automatic manipulator unit. The manipulator uses a syringe needle to form a HF of a given geometry. The needle in automatic mode is sequentially immersed, first into the polymer solution and then into the coagulation bath. The possibility of using a manipulator to obtain HF samples was studied on the known polysulfone (PSf)/N-methylpyrrolidone (NMP)/pore-forming additive system. A series of HF membrane samples were made within 29 h from twelve 1 mL PSf casting solutions. This was 15 times faster than obtaining samples of HF membranes at the multifunctional research laboratory facility. From the point of view of the consumption of the components of the casting solution, the use of the manipulator was 30 times more economical, and the consumption of water for precipitation and washing was 8000 times less. The developed method made it possible to study samples of HF by scanning electron microscopy (SEM), ultrafiltration, and evaluate its mechanical properties without spinning the membranes. Using the new technique, the optimal composition of the casting solution for the wet spinning of HF PSf membranes was selected during two weeks. Thus, the manipulator makes it possible to significantly reduce the time of the new membrane preparation, reduce the volume of used polymer, and thus makes it promising to study expensive or new membrane materials.
               