This work reports the effect of scaling up annular centrifugal contactors (ACCs) upon the residence time distribution and the efficiency of extraction of uranium. The experiments were carried out in… Click to show full abstract
This work reports the effect of scaling up annular centrifugal contactors (ACCs) upon the residence time distribution and the efficiency of extraction of uranium. The experiments were carried out in a multi-scale ACC platform of three ACCs with rotor diameters of 12, 25, and 40 mm. To enable direct comparison across all three scales of ACC, the residence time distributions were acquired by injecting dye into the solvent phase at a constant relative volume related to the ACC liquid holdup. Across all scales and flowrates, there was little difference in residence time distribution (<6 residence volumes), except for the smallest 12 mm rotor diameter ACC with a high solvent/aqueous feed ratio, which required 12 residence volumes, potentially due to internal circulation in the annulus. At low flowrates, the stage efficiency in all cases was >95%, and it improved further in larger rotor diameter ACCs.
               