Fault Seamless Self-Healing Method of Regional Distributed Network Based on the Cooperation of Source-Load-Storage

Photo by amandavickcreative from unsplash

The large-scale development of distributed generators poses challenges to the operation of distribution networks in remote areas. The power grid structure of the regional distributed networks in remote areas is… Click to show full abstract

The large-scale development of distributed generators poses challenges to the operation of distribution networks in remote areas. The power grid structure of the regional distributed networks in remote areas is relatively weak. When a fault occurs in the connecting channel, the regional distributed network may be separated from the main grid and become an island. Those distributed generators not only cannot maintain stable operation of the island but may lead to reclosing failure. This may lead to power interruption of important loads. Aiming at the demand for continuous power supply of important loads in regional distributed networks, a self-healing control method based on the cooperation of source-load-storage is proposed in this paper. The characteristics of the regional distributed network are analyzed first. A real-time island stability control method based on the operating conditions combined with regulation with tripping is proposed. This method comprehensively evaluates the self-healing ability of the regional distributed network after the island. The regulation strategy is adopted preferentially to realize the stable operation of the island without losing any load. When the regulation ability is insufficient, the strategy combines regulation and tripping. Considering the importance of load and source-load ratio, and according to the real-time power of each feeder, the optimal feeders are cut off. The purpose of island stability control of the regional distributed network was achieved. In this way, the load loss is minimized, and the speed of island re-connection to the grid is also accelerated. The seamless power supply of important loads in a regional distributed network is guaranteed. A complex Hardware-in-Loop simulation test platform of RTDS is built to verify the correctness of the proposed method.

Keywords: distributed network; self healing; regional distributed; load; island

Journal Title: Sustainability
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.