LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Anti-Scale Performance and Mechanism of Valonia Tannin Extract for Calcium Carbonate in Circulating Cooling Water System

Photo by guzmanbarquin from unsplash

Natural-polymer-based antiscalants for various calcium scales have recently received significant attention due to their prominent structural features, such as hydroxyl, amino, and organic acids, as well as their environmental friendliness… Click to show full abstract

Natural-polymer-based antiscalants for various calcium scales have recently received significant attention due to their prominent structural features, such as hydroxyl, amino, and organic acids, as well as their environmental friendliness and widespread availability. In this study, a novel green antiscalant, namely modified valonia tannin extract (MVTE), was synthesized using valonia tannin extract (VTE), itaconic acid (IA), and 2-acrylamido-2-methylpropanesulfonic acid (AMPS). The structure of MVTE was characterized by Fourier transform infrared spectroscopy (FT-IR). The crystal morphology, structure, and surface elementary composition of CaCO3 were analyzed using scanning electron microscopy (SEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS), respectively. Results indicate that MVTE with the best anti-scale performance is prepared when the valonia dosage is 2.5 g, the initiator dosage is 6 wt.%, the reaction temperature is 75 °C, and the reaction time is 3.5 h. Moreover, MVTE shows significantly improved resistance to temperature and alkalinity compared to VE. Results from SEM, XRD, and XPS demonstrate that MVTE can interfere with the regular growth of CaCO3 crystals through chelation, dispersion, and lattice distortion. This effect results in the generation of vaterite, which inhibits the deposition of CaCO3. Meanwhile, the molecular dynamics (MD) simulation was employed to further explore the anti-scale mechanisms at an atomistic level. The results illustrate that interaction energies originate from ionic and hydrogen bonds between MVTE and calcite, which ultimately improve the anti-scale performance of MVTE. In conclusion, MVTE can be an excellent antiscalant in circulating cooling water systems.

Keywords: tannin extract; spectroscopy; valonia tannin; scale performance; anti scale

Journal Title: Sustainability
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.