LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

A Preliminary Assessment of Size-Fractionated Microplastics in Indoor Aerosol—Kuwait’s Baseline

Photo from wikipedia

The omnipresence of microplastic (MP) in various environmental samples, including aerosols, has raised public health concerns; however, there is presently very limited information on MPs in indoor aerosol. This paper… Click to show full abstract

The omnipresence of microplastic (MP) in various environmental samples, including aerosols, has raised public health concerns; however, there is presently very limited information on MPs in indoor aerosol. This paper presents a unique dataset where smaller MPs have been sampled using a six-stage cascade impactor from indoor environments in Kuwait. The MP concentration in the indoor air varied between 3.2 and 27.1 particles m−3, and the relative MP concentration decreased linearly from the lowest to the highest size fraction. A significant effect of location was observed for the total number of MPs (F2,14 = 5.80, p = 0.02) and the inhalable fraction (F2,14 = 8.38, p = 0.005), while location had no effect on the respirable fraction (F2,14 = 0.54, p = 0.60). A significant effect of the type of air conditioning used was also observed for the total number of MPs (F2,19 = 5.58, p = 0.01) and the inhalable fraction (F2,19 = 6.45, p = 0.008), while location had no effect on the respirable fraction (F2,19 = 1.30, p = 0.30). For the total number of MPs and the inhalable fraction, the concentration was significantly higher for the split unit air-conditioning as compared to the central air-conditioning plants. The presence/absence of carpets had no significant effect on the MP concentrations (total: F1,19 = 4.08, p = 0.06; inhalable: F1,19 = 3.03, p = 0.10; respirable: F1,19 = 4.27, p = 0.05). The shape was dominantly fibers, with few fragments in lower size fractions. These datasets represent the first baseline information for Kuwait, and the smaller MPs in all the samples further underscore the need to develop standardized protocols of MP collection in the ≤2.5 µm fraction that can have more conspicuous health implications.

Keywords: effect; baseline; indoor aerosol; air; fraction; size

Journal Title: Toxics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.