LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Validation of a Novel Fluorescent Lateral Flow Assay for Rapid Qualitative and Quantitative Assessment of Total Anti-SARS-CoV-2 S-RBD Binding Antibody Units (BAU) from Plasma or Fingerstick Whole-Blood of COVID-19 Vaccinees

Photo by visuals from unsplash

Background: Limited commercial LFA assays are available to provide a reliable quantitative measurement of the total binding antibody units (BAU/mL) against the receptor-binding domain of the SARS-CoV-2 spike protein (S-RBD).… Click to show full abstract

Background: Limited commercial LFA assays are available to provide a reliable quantitative measurement of the total binding antibody units (BAU/mL) against the receptor-binding domain of the SARS-CoV-2 spike protein (S-RBD). Aim: To evaluate the performance of FinecareTM2019-nCoV S-RBD LFA and its fluorescent reader (FinecareTM-FIA Meter) against the following reference methods (i) The FDA-approved Genscript surrogate virus-neutralizing assay (sVNT), and (ii) three highly performing automated immunoassays: BioMerieux VIDAS, Ortho VITROS, and Mindray CL-900i. Methods: Plasma from 488 vaccinees were tested by all aforementioned assays. Fingerstick whole-blood samples from 156 vaccinees were also tested by FinecareTM. Results and conclusions: FinecareTM showed 100% specificity as none of the pre-pandemic samples tested positive. Equivalent FinecareTM results were observed among the samples taken from fingerstick or plasma (Pearson correlation r=0.9, p<0.0001), suggesting that fingerstick samples are sufficient to quantitate the S-RBD BAU/mL. A moderate correlation was observed between FinecareTM and sVNT (r=0.5, p<0.0001), indicating that FinecareTM can be used for rapid prediction of the neutralization antibody post-vaccination. FinecareTM BAU results showed strong correlation with VIDAS (r=0.6, p<0.0001), and moderate correlation with VITROS (r=0.5, p<0.0001), and CL-900 (r=0.4, p<0.0001), suggesting that FinecareTM be used as a surrogate for the advanced automated assays to measure S-RBD BAU/mL.

Keywords: finecaretm; sars cov; antibody units; binding antibody; units bau; antibody

Journal Title: Vaccines
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.