LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Septal Ablation with Radiofrequency Catheters Guided by Echocardiography for Treatment of Patients with Obstructive Hypertrophic Cardiomyopathy: Initial Experience.

Photo by yannym from unsplash

BACKGROUND Hypertrophic cardiomyopathy (HCM) can cause obstruction in the left ventricular outflow tract (LVOT), and be responsible for the onset of limiting symptoms, such as tiredness. When such symptoms are… Click to show full abstract

BACKGROUND Hypertrophic cardiomyopathy (HCM) can cause obstruction in the left ventricular outflow tract (LVOT), and be responsible for the onset of limiting symptoms, such as tiredness. When such symptoms are refractory to pharmacological treatment, interventionist alternative therapies can be useful, such as septal ablation through the infusion of alcohol in the coronary artery or through myectomy. Recently, the use of a radiofrequency (RF) catheter for endocardial septal ablation guided by electroanatomic mapping has proven to be efficient, despite the high incidence of complete atrioventricular block. An alternative would be the application of RF at the beginning point of the septal gradient guided by the transesophageal echocardiography (TEE). The echocardiography is an imaging method with high accuracy to determine septal anatomy. OBJECTIVE To assess the long term effect of septal ablation for the relief of ventricular-arterial gradient, using TEE to help place the catheter in the area of larger septal obstruction. Besides, to assess the effects of ablation on the functional class and echocardiographic parameters. METHODS Twelve asymptomatic patients, with LVOT obstruction, refractory to pharmacological therapy, underwent endocardial septal ablation with 8mm-tip catheters, whose placement was oriented in the region of larger obstruction, assisted by the TEE. Temperature-controlled and staggered RF applications were performed. After each application, the gradient was reassessed and a new application was performed according to the clinical criterion. The effects of RF applications were assessed both for the gradient at rest and for that provoked by the Valsalva maneuver, and considering the gradient. The differences were significant when p-value was lower than or equal to 0.05. RESULTS It was possible to observe that the mean reduction of the maximum gradients was from 96.8±34.7 mmHg to 62.7±25.4 mmHg three months after the procedure (p=0.0036). After one year, the mean of maximum gradient was 36.1±23.8 mmHg (p=0.0001). The procedure was well tolerated, without records of complete atrioventricular block nor severe complications. CONCLUSION The TEE-guided septal ablation was efficient and safe, and the results were maintained during the clinical follow-up period. It is a reasonable option for the interventionist treatment of LVOT obstruction in HCM.

Keywords: hypertrophic cardiomyopathy; ablation; obstruction; septal ablation; treatment; echocardiography

Journal Title: Arquivos brasileiros de cardiologia
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.