LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Refractive Changes After Implantation of Reversed Intraocular Lens in Cataract Surgery: A Mathematical Model.

Photo from wikipedia

PURPOSE To develop a mathematical model that can predict the amount of refractive change caused by implantation of an intraocular lens (IOL) in a reversed position during cataract surgery. METHODS… Click to show full abstract

PURPOSE To develop a mathematical model that can predict the amount of refractive change caused by implantation of an intraocular lens (IOL) in a reversed position during cataract surgery. METHODS A theoretical mathematical formula based on the Gullstrand eye model was constructed to estimate the refractive change of the eye after implantation of a reversed IOL. The refractive change caused by implantation of the IOL in a reversed position was calculated based on the exchange of the anterior curvature with the posterior curvature of the IOL, and the lengthening of the distance between the IOL and the retina. In case of a three-piece IOL with angulation, the amount of refractive change was calculated based on its angle and the total refractive power of the eye, which is dependent on the focal length of the eye. RESULTS Calculated refractive change for one-piece IOLs was less than 0.10 diopter (D). For three-piece IOLs, the calculated refractive change makes the eye on average 0.77 D more myopic and can increase with the total refractive power of the patient's eye. The mathematical model was applied to seven previously published cases of reverse IOL implantation. CONCLUSIONS This calculation demonstrates that with an upside-down IOL, there is a small refractive change in the one-piece IOL, including a toric IOL without angulation, but there can be a large refractive change in the three-piece IOL with angulation, especially using a higher power IOL or with a shorter axial length. [J Refract Surg. 2023;39(5):326-331.].

Keywords: refractive change; change; eye; implantation; model; iol

Journal Title: Journal of refractive surgery
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.