LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

The Effect of Positive Medial Cortical Support in Reduction of Pertrochanteric Fractures with Posteromedial Wall Defect Using a Dynamic Hip Screw

Photo from wikipedia

Background We evaluated the radiological and clinical results of reduction using a dynamic hip screw according to the grade of medial cortical support in patients with AO Foundation and Orthopaedic… Click to show full abstract

Background We evaluated the radiological and clinical results of reduction using a dynamic hip screw according to the grade of medial cortical support in patients with AO Foundation and Orthopaedic Trauma Association (AO/OTA) classification type 31-A2 pertrochanteric fractures. Methods We enrolled 100 patients with AO/OTA type 31-A2 fractures with displaced lesser trochanter fragments (length of the cortical area longer than 20 mm on the pelvis anteroposterior view). Patients with positive medial cortical support were assigned to group 1 (n = 28); neutral medial cortical support, group 2 (n = 42); and negative medial cortical support, group 3 (n = 30). Radiological evaluation was done by measuring the change in the femoral neck-shaft angle and sliding distance of the lag screw. Clinical outcomes of each group were compared by means of the walking ability score proposed by Ceder. Results Group 1 showed significantly less changes in the femoral neck-shaft angle and shorter sliding distance than groups 2 and 3. Group 2 showed significantly less changes in the femoral neck-shaft angle and shorter sliding distance than group 3. Group 1 showed significantly higher walking ability scores than group 3 (p = 0.00). The use of trochanter stabilizing plates or fixation using wires for posteromedial wall defect resulted in no significant changes in terms of the femoral neck-shaft angle or sliding distance. Conclusions In the treatment of pertrochanteric fractures accompanied by posteromedial wall defect using a dynamic hip screw, reduction with negative cortical support should be avoided.

Keywords: dynamic hip; group; cortical support; medial cortical; using dynamic

Journal Title: Clinics in Orthopedic Surgery
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.