LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Excitation-Contraction Coupling Time is More Sensitive in Evaluating Cardiac Systolic Function

Photo from wikipedia

Background: Pressure overload-induced myocardial hypertrophy is a key step leading to heart failure. Previous cellular and animal studies demonstrated that deteriorated excitation–contraction coupling occurs as early as the compensated stage… Click to show full abstract

Background: Pressure overload-induced myocardial hypertrophy is a key step leading to heart failure. Previous cellular and animal studies demonstrated that deteriorated excitation–contraction coupling occurs as early as the compensated stage of hypertrophy before the global decrease in left ventricular ejection fraction (LVEF). This study was to evaluate the cardiac electromechanical coupling time in evaluating cardiac systolic function in the early stage of heart failure. Methods: Twenty-six patients with Stage B heart failure (SBHF) and 31 healthy controls (CONs) were enrolled in this study. M-mode echocardiography was performed to measure LVEF. Tissue Doppler imaging (TDI) combined with electrocardiography (ECG) was used to measure cardiac electromechanical coupling time. Results: There was no significant difference in LVEF between SBHF patients and CONs (64.23 ± 8.91% vs. 64.52 ± 5.90%; P = 0.886). However, all four electromechanical coupling time courses (Qsb: onset of Q wave on ECG to beginning of S wave on TDI, Qst: onset of Q wave on ECG to top of S wave on TDI, Rsb: top of R wave on ECG to beginning of S wave on TDI, and Rst: top of R wave on ECG to top of S wave on TDI) of SBHF patients were significantly longer than those of CONs (Qsb: 119.19 ± 35.68 ms vs. 80.30 ± 14.81 ms, P < 0.001; Qst: 165.42 ± 60.93 ms vs. 129.04 ± 16.97 ms, P = 0.006; Rsb: 82.43 ± 33.66 ms vs. 48.30 ± 15.18 ms, P < 0.001; and Rst: 122.37 ± 36.66 ms vs. 93.25 ± 16.72 ms, P = 0.001), and the Qsb, Rsb, and Rst time showed a significantly higher sensitivity than LVEF (Rst: P =0.032; Rsb: P = 0.003; and Qsb: P = 0.004). Conclusions: The cardiac electromechanical coupling time is more sensitive than LVEF in evaluating cardiac systolic function.

Keywords: coupling time; systolic function; evaluating cardiac; time; cardiac systolic

Journal Title: Chinese Medical Journal
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.