LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Effectiveness of abdominal compression in reducing internal target motion during conformal radiotherapy for carcinoma stomach - A pilot study.

Photo by arunwithideas from unsplash

AIM : To assess the effectiveness of abdominal compression in reducing internal target motion during conformal radiotherapy for stomach cancer. MATERIALS AND METHODS A pilot study was conducted on five… Click to show full abstract

AIM : To assess the effectiveness of abdominal compression in reducing internal target motion during conformal radiotherapy for stomach cancer. MATERIALS AND METHODS A pilot study was conducted on five patients who received adjuvant radiotherapy for stomach cancer. All the patients had surgical clips and were offered radiotherapy and concurrent chemotherapy as per the institutional protocol. An abdominal compression device was developed consisting of a triangular Styrofoam's plate and an inflatable air bladder that was positioned over the patients' abdomen. The pneumatic pressure was set according to the patients' comfort. On the simulation day, patients had two computed tomography (CT)-scanning sessions, with and without abdominal compression. Target volumes and organs at risk (OAR) were delineated on the CT images without compression. On the treatment day, fluoroscopy was acquired with onboard imager (OBI) and movements of surgical clips with and without compression analyzed with the help of a tracker software. Observed values with and without abdominal compression were compared. RESULTS Abdominal compression usage has reduced the mean breathing excursion (MBE) in medio lateral(ML) direction from 5.92mm to 4.15 mm and in cranio caudal direction (CC) from 11.3mm to 7.2mm. The range of reduction by 29.85% in the ML and 36.86% in CC direction. The average residual breathing excursion was 1.766 mm (SD = 1.33 mm) in the ML and 4.02 mm (SD = 2.18 mm) in the CC direction, respectively. CONCLUSION Abdominal compression was useful in reducing internal target motion during stomach cancer conformal radiotherapy. The device we developed is patient friendly and cost-effective.

Keywords: compression; abdominal compression; reducing internal; radiotherapy; target; stomach

Journal Title: Indian journal of cancer
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended