Purpose: We aimed to evaluate the normative pupillometry values and mean pupil dilatation speed in healthy individuals in different age groups in our study. Methods: The study group included 180… Click to show full abstract
Purpose: We aimed to evaluate the normative pupillometry values and mean pupil dilatation speed in healthy individuals in different age groups in our study. Methods: The study group included 180 eyes of 90 healthy volunteers in different age groups. Group 1 consisted of 30 participants between the ages of 6 and 18, group 2 consisted of 30 participants aged 19–40, and group 3 consisted of 30 participants aged 41–75. Scotopic, mesopic, photopic, and dynamic measurements were taken with automatic pupillometry of Sirius Topographer (CSO, Firenze, Italy). The mean pupil dilation speed at the 18th second was calculated according to dynamic measurements. Results: Group 1 had a significantly larger pupil diameter than groups 2 and 3 in all static and dynamic parameters, and the mean pupil dilation speed was the highest among the groups (P < 0.001 for all static and dynamic parameters). In addition, group 2 had a significantly larger pupil diameter than group 3 (P < 0.001 for all static and dynamic parameters) and the mean pupil dilation speed was faster than group 3 (P = 0.027). Conclusion: We have presented the static and dynamic parameters and the mean speed of pupil dilatation at the 18th second with automatic pupillometry in healthy individuals in childhood, adulthood, and old age. More studies with higher participants and younger age children are needed.
               