LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Categorization of Breast Fine Needle Aspirates Using the International Academy of Cytology Yokohama System Along with Assessment of Risk of Malignancy and Diagnostic Accuracy in a Tertiary Care Centre

Photo from wikipedia

Context: The International Academy of Cytology Yokohama System has developed a standardized system of reporting breast cytology by classifying them into five categories – insufficient, benign, atypical, suspicious, and malignant.… Click to show full abstract

Context: The International Academy of Cytology Yokohama System has developed a standardized system of reporting breast cytology by classifying them into five categories – insufficient, benign, atypical, suspicious, and malignant. Numerous studies conducted at different centers are required to confirm the risk of malignancy of the different categories. Aims: The main objectives of our study were to classify breast fine needle aspirates according to the IAC Yokohama system and assess the risk of malignancy, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. Settings and Design: It was a retrospective study done over a period of 2 years from January 2018 to December 2020. Materials and Methods: All breast FNAs done in the above period were retrieved and classified into five categories according to the Yokohama system. Histopathological diagnosis was also retrieved wherever available. Statistical Analysis Used: Using a histopathological diagnosis as the gold standard, sensitivity, specificity, PPV, NPV, and diagnostic accuracy were calculated. For each of the five categories, the risk of malignancy was also assessed. Results: Out of the 554 breast fine needle aspirates, 242 had histopathological correlation. The risk of malignancy for insufficient, benign, atypical, suspicious, and malignant categories were 5%, 1.5%, 17.4%, 81.8%, and 100%, respectively. Maximum sensitivity (97.2%) was achieved when atypical, suspicious, and malignant cases were considered as positive test results. The highest specificity (100%) was observed when only malignant cases were considered as positive test results, whereas maximum diagnostic accuracy (96.4%) was noted when the malignant and suspicious category was included in positive test results. Conclusion: The IAC Yokohama system is an excellent system for accurately diagnosing breast fine needle aspirates with greater reproducibility of reports and better communication between the pathologist and clinician.

Keywords: yokohama system; risk malignancy; cytology; system

Journal Title: Journal of Cytology
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.