LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Anterior scleral thickness in patients of central serous chorioretinopathy: A Case–control study

Photo by diana_pole from unsplash

BACKGROUND: The aim of this study was to determine whether anterior scleral thickness (AST) varies significantly between patients with central serous chorioretinopathy (CSCR) versus normal individuals. To validate scleral thickness… Click to show full abstract

BACKGROUND: The aim of this study was to determine whether anterior scleral thickness (AST) varies significantly between patients with central serous chorioretinopathy (CSCR) versus normal individuals. To validate scleral thickness measurements by ultrasound biomicroscopy (UBM) vis a vis anterior segment optical coherence tomography (ASOCT). METHODS: This case–control study analyzed 50 eyes of 50 patients with CSCR (cases) and compared it with that of 50 eyes of 50 age- and gender-matched controls. In cases, AST was measured at 1 mm and 2 mm temporal to the temporal scleral spur by ASOCT and UBM. In controls, AST was measured only by ASOCT. In all participants, posterior choroidal thickness (CT) was measured subfoveally, 1 mm nasal and 1 mm temporal to fovea by enhanced depth imaging optical coherence tomography. RESULTS: The mean AST, as measured by ASOCT among cases and controls was 703.86 μm and 667.54 μm, respectively (P = 0.006). The mean AST by ASOCT and UBM in cases were 703.86 μm and 657.42 μm, respectively (P = 0.001). AST measurement by ASOCT and UBM showed a positive and statistically significant correlation (r = 0.431, P = 0.000). The mean CT among cases and controls was 443.56 μm and 373.88 μm, respectively (P = 0.000). We found a weak positive correlation (r = 0.11) in cases and weaker positive correlation in controls, between CT and AST measured by ASOCT. CONCLUSIONS: Our findings suggest that AST varies significantly between patients with CSCR versus normal individuals. We found poor agreement of AST when measured by ASOCT and UBM.

Keywords: anterior scleral; scleral thickness; ast measured; thickness; asoct; study

Journal Title: Oman Journal of Ophthalmology
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.