LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Relative Efficacy of 225Ac-PSMA-617 and 177Lu-PSMA-617 in Prostate Cancer Based on Subcellular Dosimetry

Photo by barebonesfotoes from unsplash

Objectives: Radionuclide therapy targeting prostate-specific membrane antigen (PSMA) with alpha-emitting 225Ac-PSMA-617 has shown clinical efficacy even in cases of failed therapy with beta-emitting 177Lu-PSMA-617. We investigated the efficacy of 225Ac-PSMA-617… Click to show full abstract

Objectives: Radionuclide therapy targeting prostate-specific membrane antigen (PSMA) with alpha-emitting 225Ac-PSMA-617 has shown clinical efficacy even in cases of failed therapy with beta-emitting 177Lu-PSMA-617. We investigated the efficacy of 225Ac-PSMA-617 relative to 177Lu-PSMA-617 using subcellular dosimetry. Methods: A 3-dimensional model of prostate cancer was constructed. For each decay, the absorbed and equivalent radiation dose to the cell nuclei was calculated. The relative efficacy per administered activity was calculated by taking into account the differences in residence time and tumor uptake. Results: As the tumor size increased, the absorbed dose from 225Ac-PSMA-617 increased linearly (R2: 0.99) and reached an asymptote near the maximum alpha range (85 µm), whereas the absorbed dose from 177Lu-PSMA-617 continued to increase linearly (R2: 0.99). The equivalent dose per decay was 2,320, 2,900, and 823-fold higher in favor of 225Ac-PSMA-617 compared to 177Lu-PSMA-617 in a single cell, 100 µm-radius micrometastasis, and macroscopic tumor, respectively. Per administered activity, the relative efficacy of 225Ac-PSMA-617 compared to 177Lu-PSMA-617 in respective tumor sizes was at least 3,480, 4,350, and 1,230-fold higher, and possibly 11,800, 14,900, and 4,200-fold higher considering differences in tumor uptake. Conclusion: At commonly administered 1,000-fold lower activity of 225Ac-PSMA-617 relative to 177Lu-PSMA-617, the equivalent radiation dose deposited by 225Ac-PSMA-617 is higher in measurable disease and much higher in microscopic disease compared to 177Lu-PSMA-617.

Keywords: psma 617; 177lu psma; efficacy 225ac; psma; 225ac psma

Journal Title: Molecular Imaging and Radionuclide Therapy
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.