Integrated ultrasound protocol in predicting weaning success and extubation failure: a prospective observational study

Photo from wikipedia

Background Difficulty in weaning from mechanical ventilation is encountered in appro-ximately 20% of patients in the intensive care unit. We assessed the utility of a combined lung, diaphragmatic, and cardiac… Click to show full abstract

Background Difficulty in weaning from mechanical ventilation is encountered in appro-ximately 20% of patients in the intensive care unit. We assessed the utility of a combined lung, diaphragmatic, and cardiac ultrasound protocol to predict extubation failure. Methods All patients extubated following a successful spontaneous breathing trial (SBT) were included in the study. Lung ultrasonography score (LUS), diaphragmatic thickness fraction (DTF), changes in velocity time integral (VTI) to passive leg raise at the beginning of SBT, and change in LUS following SBT were recorded. Results A total of 60 patients who underwent successful SBT were included in the study. Twenty-seven patients required either non-invasive or invasive mechanical ventilation during the next 48 hours and were classified as weaning failure (Group F). The remaining 33 patients were designated as weaning success (Group S). Compared to group S, patients in Group F had significantly longer ICU length of stay (6.96 ± 4.30 days vs. 11.66 ± 3.85 days, P < 0.001), higher LUS change during SBT (1 [0–2] vs. 2 [1–4], P < 0.001), lower DTF (30.87 ± 5.32 vs. 27.88 ± 6.24, P = 0.04), and showed lower VTI increment to PLR (13.63 ± 3.44 vs. 9.11 ± 4.59, P < 0.001). Using a binary logistic regression model, DTF < 26% (odds ratio 6.20, 95% CI: 1.06–36.04) and VTI change to PLR < 10.2% (odds ratio 6.16, 95% CI: 1.14–33.13) were found to be significant predictors of weaning failure (P < 0.05). The AUROC for VTI and DTF for predicting weaning failure were 0.79 and 0.64, respectively. Conclusions An integrated ultrasound protocol using a combination of lung, diaphragm, and cardiac sonography was a reliable predictor of weaning failure.

Keywords: extubation failure; ultrasound protocol; failure; weaning failure; study

Journal Title: Anaesthesiology Intensive Therapy
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.