LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Propafenone quantification in human plasma by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry in a bioequivalence study
.

Photo by aaronburden from unsplash

Propafenone is an antiarrhythmic drug applied to ventricular arrhythmias, initially recognized as a sodium channel blocker. This study aims to evaluate the bioequivalence of two propafenone formulations (300 mg tablet) in… Click to show full abstract

Propafenone is an antiarrhythmic drug applied to ventricular arrhythmias, initially recognized as a sodium channel blocker. This study aims to evaluate the bioequivalence of two propafenone formulations (300 mg tablet) in healthy subjects under non-fasting conditions. The study was conducted as an open, randomized, 2-period design with a 2-sequence (RT, TR) with a 1-week washout interval. The subjects were selected for the study after having their health status previously assessed by a clinical evaluation and laboratory tests (biochemical and hematological parameters, and urinalysis). Debrisoquine phenotype of healthy subjects was determined by analysis of urinary excretion of debrisoquine and its major metabolite, 4-hydroxydebrisoquine. A single propafenone tablet (300 mg) was given in each occasion. Plasma propafenone concentrations were analyzed by liquid chromatography coupled to tandem mass spectrometry (HPLC/MS/MS) with positive ion electrospray ionization using multiple reactions monitoring (MRM). The geometric mean and 90% confidence intervals (CI) of propafenone/Ritmonorm® (T/R) percent ratio were 100.44% (88.39 - 114.13%) for AUClast, 99.84% (90.31 - 110.36%) for AUCinf, and 99.30% (90.08 - 109.47%) for Cmax. Since the 90% CI for Cmax, AUClast, and AUCinf ratios were all inside the 80 - 125% interval proposed by the US Food and Drug Administration Agency, it was concluded that the propafenone formulation elaborated by Biolab Sanus Farmacêutica Ltda. is bioequivalent to Ritmonorm® formulation for both the rate and the extent of absorption. The drug was well tolerated by the subjects, indicating that it is safe to perform propafenone bioequivalence studies in healthy subjects with intermediate/extensive metabolism.
.

Keywords: bioequivalence; study; liquid chromatography; propafenone; chromatography coupled; tandem mass

Journal Title: International journal of clinical pharmacology and therapeutics
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.