LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

To: Comparison of bronchial hygiene techniques in mechanically ventilated patients: a randomized clinical trial

Photo by chuttersnap from unsplash

In this issue of Revista Brasileira de Terapia Intensiva, Naue et al.(1) present an interesting study. We would like to congratulate the authors for their relevant contribution to the scientific… Click to show full abstract

In this issue of Revista Brasileira de Terapia Intensiva, Naue et al.(1) present an interesting study. We would like to congratulate the authors for their relevant contribution to the scientific literature on the subject, but we need clarification on the study design and reporting. The results of the study show that hyperinflation with a mechanical ventilator (HMV)+vibrocompression (VB) increased the amount of aspirated secretions, which did not occur with the other techniques. However, when HMV was applied alone and compared to pulmonary aspiration alone (ASP), the amount of secretion removed did not differ significantly, and worse, according to figure 3, it appears that ASP was able to remove more secretions than HMV, although there was no statistical significance. This led us to reflect on the reason why HMV, particularly the way it was performed, could have yielded the opposite effect to that proposed; that is, why did it displace the secretion towards the periphery of the lungs? In the protocol used, HMV was performed in a pressure-controlled mode (which the authors erroneously classified as a “pressure cycling mode”), with inspiratory pressure increasing until a peak pressure of 40cmH2O was reached. We believe that the use of pressure-controlled modes does not favor a peak expiratory flow 10% higher than the peak inspiratory flow, which is necessary for the displacement of mucus towards the glottis by two-phase liquid-gas interaction (expiratory flow bias).(2) Thomas(3) demonstrated in a bench model that a ventilation mode with volume control/flow is more successful in achieving an expiratory flow bias, which is theoretically necessary for adequate clearance of the pulmonary secretions. This is due to the ability to control peak inspiratory flow, which is not possible in pressure-controlled modes: in these, the inspiratory flow is variable and adapts according to respiratory system compliance, airway resistance and patient inspiratory effort. In a randomized crossover study, Amaral et al.(4) observed that the expiratory flow bias was significantly greater in volume-controlled mode than in pressure-controlled mode. By increasing the inspiratory pressure, the authors demonstrated an increase in inspiratory flow in a ratio at least proportional to the expiratory flow, reducing the chances of obtaining a PIF/PEF ratio ≤ 0.9, which is necessary to move the mucus in the direction to the glottis. Our question is: if the HMV had been performed in volume-controlled mode, could there have been more effective secretion clearance?(2) Angelo Roncalli Miranda Rocha1, George Ntoumenopoulos2, Luiz Alberto Forgiarini Júnior3

Keywords: pressure controlled; inspiratory; controlled mode; pressure; expiratory flow; flow

Journal Title: Revista Brasileira de Terapia Intensiva
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.