Performance of the European Society of Cardiology 0/1-Hour, 0/2-Hour, and 0/3-Hour Algorithms for Rapid Triage of Acute Myocardial Infarction

Photo from wikipedia

BACKGROUND The 2020 European Society of Cardiology (ESC) guidelines recommend using the 0/1-hour and 0/2-hour algorithms over the 0/3-hour algorithm as the first and second choices of high-sensitivity cardiac troponin… Click to show full abstract

BACKGROUND The 2020 European Society of Cardiology (ESC) guidelines recommend using the 0/1-hour and 0/2-hour algorithms over the 0/3-hour algorithm as the first and second choices of high-sensitivity cardiac troponin (hs-cTn)-based strategies for triage of patients with suspected acute myocardial infarction (AMI). PURPOSE To evaluate the diagnostic accuracies of the ESC 0/1-hour, 0/2-hour, and 0/3-hour algorithms. DATA SOURCES PubMed, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus from 1 January 2011 to 31 December 2020. (PROSPERO: CRD42020216479). STUDY SELECTION Prospective studies that evaluated the ESC 0/1-hour, 0/2-hour, or 0/3-hour algorithms in adult patients presenting with suspected AMI. DATA EXTRACTION The primary outcome was index AMI. Twenty unique cohorts were identified. Primary data were obtained from investigators of 16 cohorts and aggregate data were extracted from 4 cohorts. Two independent authors assessed each study for methodological quality. DATA SYNTHESIS A total of 32 studies (20 cohorts) with 30 066 patients were analyzed. The 0/1-hour algorithm had a pooled sensitivity of 99.1% (95% CI, 98.5% to 99.5%) and negative predictive value (NPV) of 99.8% (CI, 99.6% to 99.9%) for ruling out AMI. The 0/2-hour algorithm had a pooled sensitivity of 98.6% (CI, 97.2% to 99.3%) and NPV of 99.6% (CI, 99.4% to 99.8%). The 0/3-hour algorithm had a pooled sensitivity of 93.7% (CI, 87.4% to 97.0%) and NPV of 98.7% (CI, 97.7% to 99.3%). Sensitivity of the 0/3-hour algorithm was attenuated in studies that did not use clinical criteria (GRACE score <140 and pain-free) compared with studies that used clinical criteria (90.2% [CI, 82.9 to 94.6] vs. 98.4% [CI, 88.6 to 99.8]). All 3 algorithms had similar specificities and positive predictive values for ruling in AMI, but heterogeneity across studies was substantial. Diagnostic performance was similar across the hs-cTnT (Elecsys; Roche), hs-cTnI (Architect; Abbott), and hs-cTnI (Centaur/Atellica; Siemens) assays. LIMITATION Diagnostic accuracy, inclusion and exclusion criteria, and cardiac troponin sampling time varied among studies. CONCLUSION The ESC 0/1-hour and 0/2-hour algorithms have higher sensitivities and NPVs than the 0/3-hour algorithm for index AMI. PRIMARY FUNDING SOURCE National Taiwan University Hospital.

Keywords: hour algorithms; hour algorithm; cardiology; hour hour; hour

Journal Title: Annals of Internal Medicine
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.