LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Effect of Virus Inactivation by Heating on Routine Clinical Laboratory Indicators in Serum.

Photo by fusion_medical_animation from unsplash

BACKGROUND Highly infectious viruses such as SARS-CoV-2, MERS-CoV, and Ebola virus represent a threat to clinical laboratory workers. We aimed to investigate how virus inactivation by heating at 60°C for… Click to show full abstract

BACKGROUND Highly infectious viruses such as SARS-CoV-2, MERS-CoV, and Ebola virus represent a threat to clinical laboratory workers. We aimed to investigate how virus inactivation by heating at 60°C for 1 hour affects routine clinical laboratory indicators. METHODS Each collected serum sample was separated into two aliquots, and various indicators were measured in first aliquot after inactivation by heating at 60°C for 1 hour and in the second after room-temperature incubation for 1 hour. RESULTS Serological test results for 36 indicators remained mostly unaffected by heat inactivation, with a mean estimated bias of < 10%. By contrast, the results for alanine transaminase, pseudocholinesterase, creatine kinase, lactate dehydrogenase, cardiac troponin I, and myoglobin were affected by heat inactivation, with the mean esti-mated bias here being > 20%, which was further increased in the case of the results for alkaline phosphatase, lipase, and creatine kinase isoenzyme MB. Immunological serological measurements showed good agreement according to Kappa consistency checks after heat inactivation of serum. The results for alanine transaminase, pseudocholinesterase, creatine kinase, lactate dehydrogenase, cardiac troponin I, and myoglobin were significantly correlated (r > 0.95) after heat inactivation, and after correction by using a regression equation, the results for the indicators still retained a clinical reference value. CONCLUSIONS Inactivation by heating at 60°C for 1 hour exerts no marked effect on numerous routine biochemical and immunological indicators in serum, but the detection values for certain items are significantly decreased. Our method could serve as reference strategy for routine serological diagnostics in patients with suspected or confirmed infection with highly pathogenic viruses.

Keywords: virus inactivation; inactivation; clinical laboratory; inactivation heating

Journal Title: Clinical laboratory
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.