Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2017 at "Scientific Reports"
DOI: 10.1038/s41598-017-06603-3
Abstract: Quantitative 99mTc-MIBI thyroid scintigraphy is a useful tool in differentiating malignant from benign thyroid nodules with indeterminate cytology. The aim of our report is to compare the diagnostic performance of different quantitative methods. We prospectively…
read more here.
Keywords:
cytology;
nodules indeterminate;
indeterminate cytology;
99mtc mibi ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2017 at "Medicine"
DOI: 10.1097/md.0000000000008038
Abstract: Abstract We use the Hill function to analyze the dynamics of Tc-99m 2 methoxy-isobutyl-isonitrile (99mTc-MIBI) scintigraphy data and to examine the earlier lower extremity microvascular perfusion of diabetic patients without typical clinical symptoms and with…
read more here.
Keywords:
lower extremity;
99mtc mibi;
mibi scintigraphy;
Sign Up to like & get
recommendations!
1
Published in 2023 at "Medicine"
DOI: 10.1097/md.0000000000033068
Abstract: Background: 99mTc-sestamibi single photon emission tomography (SPECT) method is widely used for imaging coronary artery disease (CAD). 82-Rubidium-PET is an alternative method that can be used to perform the same purpose. Purpose/Aim: This study aims…
read more here.
Keywords:
99mtc mibi;
rubidium pet;
spect;
value ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2018 at "Nuclear Medicine Communications"
DOI: 10.1097/mnm.0000000000000880
Abstract: Background The intense liver uptake of technetium-99-sestamibi (99mTc-MIBI) and photon scattering from the liver cause problems in quantitative perfusion interpretation. Hence, 99mTc-MIBI is a substrate for P-glycoprotein pump; variations in P-glycoprotein levels may affect liver…
read more here.
Keywords:
john wort;
liver clearance;
accelerates liver;
technetium sestamibi ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2019 at "Nuclear Medicine Communications"
DOI: 10.1097/mnm.0000000000000931
Abstract: Background The aim of this study was to evaluate the behavioral uptake and ability to diagnose pituitary adenoma (PA) using tumor-seeking radiopharmaceuticals, and to provide a semiquantitative analysis of tracer uptake in the pituitary region.…
read more here.
Keywords:
99mtc hynic;
hynic toc;
99mtc mibi;
mibi spect ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2021 at "Clinical nuclear medicine"
DOI: 10.1097/rlu.0000000000003701
Abstract: ABSTRACT A 45-year-old woman, who had endoscopic parathyroidectomy 5 years ago for a right inferior parathyroid adenoma, underwent 99mTc-MIBI scan for the evaluation of recurrent parathyroidism. The images did not identify any abnormal uptake in…
read more here.
Keywords:
parathyroid adenoma;
pectoralis major;
99mtc mibi;
endoscopic parathyroidectomy ... See more keywords
Sign Up to like & get
recommendations!
2
Published in 2022 at "Clinical nuclear medicine"
DOI: 10.1097/rlu.0000000000004011
Abstract: ABSTRACT A 50-year-old woman with end-stage renal disease presented with recurrent hyperparathyroidism after parathyroidectomy. 99mTc-MIBI scintigraphy did not show MIBI-avid lesion in the neck or mediastinum but in bilateral lung fields instead. On suspicion of…
read more here.
Keywords:
99mtc mibi;
fdg;
parathyroid hyperplasia;
mibi scintigraphy ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
2
Published in 2022 at "Clinical nuclear medicine"
DOI: 10.1097/rlu.0000000000004070
Abstract: ABSTRACT A 26-year-old woman was incidentally discovered to have bilateral renal tumors on ultrasound, and percutaneous biopsy of the right kidney lesion proved eosinophilic solid and cystic renal cell carcinoma. 18F-FDG PET/CT demonstrated hyperdense or…
read more here.
Keywords:
eosinophilic solid;
renal cell;
cystic renal;
solid cystic ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2022 at "Clinical nuclear medicine"
DOI: 10.1097/rlu.0000000000004079
Abstract: ABSTRACT MIBI scintigraphy is the most widely used modality to identify parathyroid adenomas preoperatively. However, MIBI is also known to accumulate in multiple benign and malignant lesions. In renal cell carcinoma, 30% of the patients…
read more here.
Keywords:
renal cell;
cell carcinoma;
metastasis;
99mtc mibi ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2020 at "Annals of Surgical Oncology"
DOI: 10.1245/s10434-020-08428-3
Abstract: Persistent primary hyperparathyroidism (PHPT) occurs in 2.5% to 15% of cases after parathyroidectomy. Few studies have evaluated the best pre-reoperative imaging approaches for persistent sporadic PHPT. This retrospective multicenter study aimed to evaluate the benefit…
read more here.
Keywords:
patients persistent;
reoperation;
mibi;
second 99mtc ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Hellenic journal of nuclear medicine"
DOI: 10.1967/s002449910506
Abstract: OBJECTIVE Primary hyperparathyroidism (pHPT) is characterised by increased parathyroid hormone (PTH) secretion and consequently increased plasma calcium. During the last few decades parathyroid scintigraphy (PS), is applied in almost all patients with pPHT before surgery…
read more here.
Keywords:
plasma calcium;
parathyroid;
subtraction;
total plasma ... See more keywords