Articles with "abdominal pressure" as a keyword



An assessment of techniques and practices used to elevate intra‐abdominal pressure when assessing pelvic floor dysfunction

Sign Up to like & get
recommendations!
Published in 2021 at "Neurourology and Urodynamics"

DOI: 10.1002/nau.24617

Abstract: To determine terminology and methods for raising intra‐abdominal pressure (IAP) currently used by clinicians to assess pelvic floor dysfunction (PFD) and to measure the effect of these maneuvers on IAP. read more here.

Keywords: floor dysfunction; pelvic floor; intra abdominal; abdominal pressure ... See more keywords

The physiological determinants of symptom burden in cirrhosis with ascites

Sign Up to like & get
recommendations!
Published in 2024 at "United European Gastroenterology Journal"

DOI: 10.1002/ueg2.12675

Abstract: Abstract Background & Aims Paracentesis is commonly used to manage patient discomfort due to ascites. The relationship between ascites pressure, ascites volume, and patient discomfort has not been elucidated. Methods We prospectively enrolled adult patients… read more here.

Keywords: pressure; symptom burden; determinants symptom; paracentesis ... See more keywords

Renaissance of the autologous pubovaginal sling

Sign Up to like & get
recommendations!
Published in 2017 at "International Urogynecology Journal"

DOI: 10.1007/s00192-017-3521-2

Abstract: Autologous tissue has been used to treat female stress urinary incontinence (SUI) for almost a century, with many operative modifications introduced throughout the years of the standard procedure known as pubovaginal sling (PVS) [1]. Currently,… read more here.

Keywords: bladder; abdominal pressure; pubovaginal sling; sling ... See more keywords
Photo from wikipedia

Embodiment of intra-abdominal pressure in a flexible multibody model of the trunk and the spinal unloading effects during static lifting tasks.

Sign Up to like & get
recommendations!
Published in 2021 at "Biomechanics and modeling in mechanobiology"

DOI: 10.1007/s10237-021-01465-1

Abstract: The role of intra-abdominal pressure (IAP) in spinal load reduction has remained controversial, partly because previous musculoskeletal models did not introduce the pressure generating mechanism. In this study, an integrated computational methodology is proposed to… read more here.

Keywords: methodology; abdominal pressure; flexible multibody; lifting tasks ... See more keywords

A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Clinical Monitoring and Computing"

DOI: 10.1007/s10877-020-00561-4

Abstract: This review presents an overview of previously reported non-invasive intra-abdominal pressure (IAP) measurement techniques. Each section covers the basic physical principles and methodology of the various measurement techniques, the experimental results, and the advantages and… read more here.

Keywords: abdominal pressure; intra abdominal; measurement; non invasive ... See more keywords
Photo from wikipedia

P1714INTRA-ABDOMINAL PRESSURE IS ASSOCIATED WITH HIGHER RENAL RESISTIVE INDEX AFTER RENAL TRANSPLANTATION

Sign Up to like & get
recommendations!
Published in 2020 at "Nephrology Dialysis Transplantation"

DOI: 10.1093/ndt/gfaa142.p1714

Abstract: The renal arterial resistive index (RRI) reflects renal hemodynamics non-invasively using Doppler arterial waveforms. RRI is defined by factors such as age, sex, weight, height or mean arterial pressure. Intra-abdominal hypertension (IAH) is a common… read more here.

Keywords: resistive index; iap; abdominal pressure; rri ... See more keywords

Effect of Increased Intra-abdominal Pressure on the Esophagogastric Junction

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Clinical Gastroenterology"

DOI: 10.1097/mcg.0000000000001756

Abstract: With the advent of high-resolution esophageal manometry, it is recognized that the antireflux barrier receives a contribution from both the lower esophageal sphincter (intrinsic sphincter) and the muscle of the crural diaphragm (extrinsic sphincter). Further,… read more here.

Keywords: sphincter; increased intra; abdominal pressure; pressure ... See more keywords

Intra-Abdominal Pressure Measurement Devices

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Wound, Ostomy and Continence Nursing"

DOI: 10.1097/won.0000000000000871

Abstract: PURPOSE: The purpose of this Technologic Analysis is to review devices designed to measure intra-abdominal pressure (IAP); these devices are used to detect intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS). APPROACH: Published literature focusing… read more here.

Keywords: measure iap; measurement devices; abdominal pressure; intra abdominal ... See more keywords

Knowledge, attitude and practice related to intra‐abdominal pressure measurement among intensive care unit nurses and determinant factors: A regional multicentre cross‐sectional study

Sign Up to like & get
recommendations!
Published in 2025 at "Nursing in Critical Care"

DOI: 10.1111/nicc.70035

Abstract: Intra‐abdominal hypertension is a common serious complication in critically ill patients. Intra‐abdominal pressure (IAP) measurement is the only reliable method of detecting and managing IAP. Various factors influence the knowledge, attitude and practice of IAP… read more here.

Keywords: attitude practice; intra abdominal; knowledge attitude; measurement ... See more keywords

Intra‐Abdominal Pressure Measurement Knowledge, Attitude, and Practice of Chinese ICU Nurses: A Cross‐Sectional Survey

Sign Up to like & get
recommendations!
Published in 2025 at "Nursing in Critical Care"

DOI: 10.1111/nicc.70181

Abstract: Intra‐abdominal pressure (IAP) measurement is an important parameter for intensive care unit (ICU) patients, helping ICU nurses identify and respond to intra‐abdominal hypertension (IAH) and changes in patient condition. The quality of IAP measurement depends… read more here.

Keywords: knowledge attitude; intra abdominal; icu nurses; measurement ... See more keywords
Photo from wikipedia

Supine equilibration of extracellular fluid in peritoneal dialysis varies with intra-abdominal pressure

Sign Up to like & get
recommendations!
Published in 2020 at "Peritoneal Dialysis International"

DOI: 10.1177/0896860819895176

Abstract: Background: Increased intra-abdominal pressure (PIA) leads to venous congestion in splanchnic and adjoining circulations. The aim is to examine whether PIA in peritoneal dialysis (PD) affects the mobilization of extracellular fluid from the lower body… read more here.

Keywords: fluid; abdominal pressure; peritoneal dialysis; supine ... See more keywords