Articles with "advanced hybrid" as a keyword



Photo by apchf from unsplash

Successful transitioning children and adolescents with type 1 diabetes from multiple daily injections to advanced hybrid closed-loop system in 10 days: a prospective intervention study on MiniMed 780G system

Sign Up to like & get
recommendations!
Published in 2022 at "Acta Diabetologica"

DOI: 10.1007/s00592-022-01851-w

Abstract: One of the latest automated insulin Delivery (AID) systems is the advanced hybrid closed-loop (AHCL), the MiniMed 780G system (Medtronic, Northridge, CA, USA), which automatically delivers basal insulin with a customizable glucose target in addition… read more here.

Keywords: system; closed loop; hybrid closed; advanced hybrid ... See more keywords
Photo from wikipedia

Cost-Effectiveness of Intermittently Scanned Continuous Glucose Monitoring Versus Advanced Hybrid Closed-Loop Systems in Type 1 Diabetes: Comment on Jendle et al.

Sign Up to like & get
recommendations!
Published in 2022 at "Diabetes Therapy"

DOI: 10.1007/s13300-022-01251-x

Abstract: A recent publication in Diabetes Therapy from Jendle and colleagues [1] reports on the costeffectiveness of the MiniMed 780G advanced hybrid closed-loop (AHCL) system (Medtronic, Northridge, CA) in people with type 1 diabetes (T1DM) in… read more here.

Keywords: advanced hybrid; system; cost effectiveness; cost ... See more keywords
Photo from wikipedia

A Response to: Letter to the Editor with Regard to the Cost-Effectiveness of an Advanced Hybrid Closed-Loop System in People with Type 1 Diabetes: A Health Economic Analysis in Sweden

Sign Up to like & get
recommendations!
Published in 2022 at "Diabetes Therapy"

DOI: 10.1007/s13300-022-01252-w

Abstract: We would like to thank Levrat-Guillen and Ghazi for their interest in our recent analysis relating to the cost-effectiveness of advanced hybrid closed-loop (AHCL) insulin delivery relative to intermittently scanned continuous glucose monitoring (isCGM) in… read more here.

Keywords: advanced hybrid; effectiveness advanced; study; cost effectiveness ... See more keywords

A comparison of two hybrid closed-loop systems in adolescents and young adults with type 1 diabetes (FLAIR): a multicentre, randomised, crossover trial

Sign Up to like & get
recommendations!
Published in 2021 at "The Lancet"

DOI: 10.1016/s0140-6736(20)32514-9

Abstract: BACKGROUND Management of type 1 diabetes is challenging. We compared outcomes using a commercially available hybrid closed-loop system versus a new investigational system with features potentially useful for adolescents and young adults with type 1… read more here.

Keywords: advanced hybrid; system; closed loop; loop system ... See more keywords
Photo by muff from unsplash

Advanced Hybrid Positioning System of SEM and AFM for 2D Material Surface Metrology

Sign Up to like & get
recommendations!
Published in 2022 at "Microscopy and Microanalysis"

DOI: 10.1017/s1431927622000903

Abstract: Abstract As the measurement scale shrinks, the reliability of nanoscale measurement is even more crucial for a variety of applications, including semiconductor electronics, optical metamaterials, and sensors. Specifically, it is difficult to measure the nanoscale… read more here.

Keywords: positioning system; sem afm; advanced hybrid; hybrid positioning ... See more keywords
Photo from wikipedia

On the Implementation of Advanced Hybrid Controllers of AC/DC Converters

Sign Up to like & get
recommendations!
Published in 2017 at "IEEE Latin America Transactions"

DOI: 10.1109/tla.2017.8015052

Abstract: The implementation of hybrid controllers in power electronics is specially challenging due to the fast processing and measurement requirements of the controller to achieve good performance. In this paper, an advanced hybrid control for a… read more here.

Keywords: implementation advanced; advanced hybrid; controllers converters; controller ... See more keywords
Photo from wikipedia

Randomised controlled trial of Advanced Hybrid Closed Loop in an Adult Population with Type 1 Diabetes (ADAPT): study protocol and rationale

Sign Up to like & get
recommendations!
Published in 2022 at "BMJ Open"

DOI: 10.1136/bmjopen-2021-050635

Abstract: Introduction For many people with type 1 diabetes who struggle to achieve glycaemic control with multiple daily injections of insulin (MDI) plus self-monitoring of blood glucose, MDI plus intermittently scanned continuous glucose monitoring (IS-CGM) or… read more here.

Keywords: cgm; study; type diabetes; trial ... See more keywords
Photo by ldxcreative from unsplash

Advanced Hybrid Closed Loop in Adult Population With Type 1 Diabetes: A Substudy From the ADAPT Randomized Controlled Trial in Users of Real-Time Continuous Glucose Monitoring.

Sign Up to like & get
recommendations!
Published in 2023 at "Journal of diabetes science and technology"

DOI: 10.1177/19322968231161320

Abstract: BACKGROUND This analysis reports the findings from a predefined exploratory cohort (cohort B) from the ADAPT (ADvanced Hybrid Closed Loop Study in Adult Population with Type 1 Diabetes) study. Adults with type 1 diabetes (T1D)… read more here.

Keywords: mdi cgm; advanced hybrid; hybrid closed; group ... See more keywords
Photo from wikipedia

Comparison of the Sensor-Augmented Pump System with the Advanced Hybrid Closed-Loop delivery System: Quality of Life, Diabetes Distress, and Glycaemic Outcomes in a Real-Life Context.

Sign Up to like & get
recommendations!
Published in 2023 at "Current diabetes reviews"

DOI: 10.2174/1573399820666230531161858

Abstract: BACKGROUND Type 1 diabetes mellitus (T1D) is a chronic disease that requires exogenous insulin administration and intensive management to prevent any complications. Recent innovations in T1D management technologies include the Advanced Hybrid Closed Loop delivery… read more here.

Keywords: system; diabetes distress; advanced hybrid; hybrid closed ... See more keywords
Photo from wikipedia

Impact of Advanced Hybrid Closed Loop on Youth With High-Risk Type 1 Diabetes Using Multiple Daily Injections.

Sign Up to like & get
recommendations!
Published in 2023 at "Diabetes care"

DOI: 10.2337/dc22-1971

Abstract: OBJECTIVE To evaluate glycemic outcomes in youth (aged 13-25 years) with type 1 diabetes and high-risk glycemic control (HbA1c ≥8.5% [69 mmol/mol]) on multiple daily injection (MDI) therapy after transitioning to advanced hybrid closed loop… read more here.

Keywords: advanced hybrid; high risk; hybrid closed; multiple daily ... See more keywords
Photo by apchf from unsplash

Patient reported outcome measures in children and adolescents with type 1 diabetes using advanced hybrid closed loop insulin delivery

Sign Up to like & get
recommendations!
Published in 2022 at "Frontiers in Endocrinology"

DOI: 10.3389/fendo.2022.967725

Abstract: Purpose To determine the impact of advanced hybrid closed - loop (AHCL) insulin delivery on quality of life, metabolic control and time in range (TIR) in youth with type 1 diabetes mellitus (T1DM). Methods Twenty-four… read more here.

Keywords: advanced hybrid; hybrid closed; closed loop; children adolescents ... See more keywords