Articles with "air cooled" as a keyword



Photo from wikipedia

An improved electrothermal‐coupled model for the temperature estimation of an air‐cooled battery pack

Sign Up to like & get
recommendations!
Published in 2019 at "International Journal of Energy Research"

DOI: 10.1002/er.5058

Abstract: This work establishes an improved electrothermal‐coupled model for the estimation of the temperature evolution in an air‐cooled pack with three parallel branches and four serial cells in each branch. This model includes the influences of… read more here.

Keywords: improved electrothermal; pack; model; temperature ... See more keywords
Photo from wikipedia

Influences of Lateral Double-Layered Deflectors on Cooling Performance of Air-Cooled Condenser

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of Thermal Science"

DOI: 10.1007/s11630-021-1443-2

Abstract: The cooling performance of air-cooled condenser (ACC) is susceptible to adverse impacts of ambient winds. In this work, three kinds of lateral double-layered deflectors installed under the ACC platform are proposed to weaken the unfavorable… read more here.

Keywords: performance air; performance; air; cooling performance ... See more keywords
Photo from wikipedia

Transient performance of air-cooled condensing heat exchanger in long-term passive cooling system under decay heat load

Sign Up to like & get
recommendations!
Published in 2017 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2016.12.033

Abstract: Abstract The transient performance of an air-cooled condensing heat exchanger in a long-term passive cooling system was evaluated under a decay heat load modeled by the ANS-73 curve. An experiment was conducted in a 1/2500-volume… read more here.

Keywords: condensing heat; decay heat; heat exchanger; cooled condensing ... See more keywords
Photo from archive.org

Circularly arranged air-cooled condensers to restrain adverse wind effects

Sign Up to like & get
recommendations!
Published in 2017 at "Applied Thermal Engineering"

DOI: 10.1016/j.applthermaleng.2017.06.001

Abstract: Abstract Ambient winds may deteriorate the thermo-flow performances of air-cooled condenser (ACC) due to its geometry defects to a certain extent. In this work, a novel circular array of ACCs is proposed to restrain the… read more here.

Keywords: wind; adverse wind; wind effects; air ... See more keywords
Photo from wikipedia

System-level analysis of a novel air-cooled condenser using spray freezing of phase change materials

Sign Up to like & get
recommendations!
Published in 2018 at "Applied Thermal Engineering"

DOI: 10.1016/j.applthermaleng.2017.11.145

Abstract: Abstract A comprehensive system-level analysis is performed for a novel air-cooled condenser based on spray freezing of phase change materials (PCMs). This novel air-cooled condenser uses PCMs to decouple the process of steam condensation and… read more here.

Keywords: phase; spray freezing; air; air cooled ... See more keywords
Photo from wikipedia

Thermo-economic comparison of air-cooled and cooling tower based Organic Rankine Cycle (ORC) with R245fa and R1233zde as candidate working fluids for different geographical climate conditions

Sign Up to like & get
recommendations!
Published in 2017 at "Energy"

DOI: 10.1016/j.energy.2017.01.134

Abstract: This article compares the part-load operation of air cooled and cooling tower based low-medium temperature geothermal Organic Rankine Cycle (ORC) systems installed at different geographical locations. Working fluid R245fa was compared with a newer competitor… read more here.

Keywords: cooling tower; air cooled; system; tower based ... See more keywords
Photo from wikipedia

Workload management for air-cooled data centers: An energy and exergy based approach

Sign Up to like & get
recommendations!
Published in 2020 at "Energy"

DOI: 10.1016/j.energy.2020.118485

Abstract: Abstract The energy required to cool an air-cooled data center (DC) contributes significantly to the cost of operation, which is further exacerbated due to a poor choice of cooling architecture and ineffective IT workload management.… read more here.

Keywords: cooled data; energy; workload management; energy exergy ... See more keywords
Photo from wikipedia

Effect of adding vortex promoter on the performance improvement of active air-cooled proton exchange membrane fuel cells

Sign Up to like & get
recommendations!
Published in 2021 at "Energy"

DOI: 10.1016/j.energy.2021.120104

Abstract: Abstract A novel method based on the Karman vortex street phenomenon for optimising air-cooled fuel cell cooling is pioneered in this paper. A vortex promoter is added to the fuel cell air inlet to create… read more here.

Keywords: effect; fuel; fuel cell; air cooled ... See more keywords
Photo from wikipedia

Annularly arranged air-cooled condenser to improve cooling efficiency of natural draft direct dry cooling system

Sign Up to like & get
recommendations!
Published in 2018 at "International Journal of Heat and Mass Transfer"

DOI: 10.1016/j.ijheatmasstransfer.2017.11.031

Abstract: Abstract For natural draft direct dry cooling system, the triangularly arranged air-cooled condenser may lead to the unexpected airflow deviations and unbalanced flow distributions although with an additional buoyancy force from the dry-cooling tower. In… read more here.

Keywords: cooled condenser; air; dry cooling; air cooled ... See more keywords
Photo from wikipedia

Effects of geometric structures of air deflectors on thermo-flow performances of air-cooled condenser

Sign Up to like & get
recommendations!
Published in 2018 at "International Journal of Heat and Mass Transfer"

DOI: 10.1016/j.ijheatmasstransfer.2017.11.071

Abstract: Abstract Ambient winds may deteriorate the thermo-flow performances of air-cooled condenser (ACC) in power plants, so it is of benefit to the energy efficient operation of ACC to propose measures against adverse wind effects. In… read more here.

Keywords: air deflectors; performances air; air; air cooled ... See more keywords
Photo from wikipedia

Air pre-heating for anti-freezing of air-cooled heat exchanger by spraying flue gas

Sign Up to like & get
recommendations!
Published in 2019 at "International Journal of Heat and Mass Transfer"

DOI: 10.1016/j.ijheatmasstransfer.2019.04.047

Abstract: Abstract In cold winter, natural draft dry cooling system (NDDCS) confronts a severe freezing risk due to high cooling capacity of ambient air. In this work, the anti-freezing of air-cooled heat exchanger by spraying flue… read more here.

Keywords: flue gas; air; cooled heat; air cooled ... See more keywords