Articles with "air supply" as a keyword



Impact of primary and secondary air supply intensity in stove on emissions of size-segregated particulate matter and carbonaceous aerosols from apple tree wood burning

Sign Up to like & get
recommendations!
Published in 2018 at "Atmospheric Research"

DOI: 10.1016/j.atmosres.2017.11.010

Abstract: Abstract In order to assess emission factors (EF) more accurately from household biomass burning, a series of laboratory-controlled apple tree wood burning tests were conducted to measure the EFs of size-segregated particulate matter (PM) and… read more here.

Keywords: tree wood; apple tree; air; wood burning ... See more keywords

Thermal comfort criteria for personal air supply in aircraft cabins in winter

Sign Up to like & get
recommendations!
Published in 2017 at "Building and Environment"

DOI: 10.1016/j.buildenv.2017.09.005

Abstract: Abstract Personal air supply systems (PASSs) have shown great potential in buildings, but to date, the usefulness of PASSs in aircraft cabins in winter has not been examined. In this study, 40 subjects participated in… read more here.

Keywords: air; aircraft cabins; air supply; personal air ... See more keywords
Photo from wikipedia

Air supply parameter optimization of a custom nonuniform temperature field based on the POD method

Sign Up to like & get
recommendations!
Published in 2021 at "Building and Environment"

DOI: 10.1016/j.buildenv.2021.108328

Abstract: Abstract In a traditional indoor environment, when a single environmental parameter is changed, the entire room is taken as the object of adjustment. Different locations in the same space may have different needs. In this… read more here.

Keywords: room; field; air supply; method ... See more keywords

Factors affecting overall and local temperature distribution in aircraft cabins

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of building engineering"

DOI: 10.1016/j.jobe.2018.03.013

Abstract: Abstract Temperature is an important factor that influences the comfort of passengers during journeys in an aircraft. The aim of this paper is to investigate the characteristics of mean temperature inside an aircraft cabin mockup… read more here.

Keywords: aircraft; temperature; air; air supply ... See more keywords

Experimental investigation on thermal management for small container data center

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Building Engineering"

DOI: 10.1016/j.jobe.2018.10.031

Abstract: Abstract The energy consumptions of data centers are increasing dramatically and cooling systems using for controlling the operating temperature usually consume more than half of these energy. Thus, effective strategies on thermal management in data… read more here.

Keywords: air supply; container data; rack; thermal management ... See more keywords

Improvement of flotation recovery using oscillatory air supply

Sign Up to like & get
recommendations!
Published in 2019 at "Minerals Engineering"

DOI: 10.1016/j.mineng.2018.11.031

Abstract: Abstract The present work compares the flotation recoveries of silica at different particle sizes with oscillatory air supply and conventional steady air supply. The flotation tests were carried out at continuous mode using a 50 mm… read more here.

Keywords: flotation recovery; flotation; air supply;
Photo from wikipedia

Hybrid diagnosis method for initial faults of air supply systems in proton exchange membrane fuel cells

Sign Up to like & get
recommendations!
Published in 2021 at "Renewable Energy"

DOI: 10.1016/j.renene.2021.07.079

Abstract: Abstract Fault diagnosis technology has been developed to improve the reliability of fuel cell systems in pursuit of successful commercialization. In this study, a hybrid fault diagnosis method is proposed to improve diagnosable fault magnitudes… read more here.

Keywords: diagnosis; diagnosis method; air supply; method ... See more keywords
Photo from wikipedia

Decoupling Control of Fuel Cell Air Supply System Based on Data-Driven Feedforward and Adaptive Generalized Supertwisting Algorithm

Sign Up to like & get
recommendations!
Published in 2025 at "IEEE Transactions on Circuits and Systems I: Regular Papers"

DOI: 10.1109/tcsi.2025.3526144

Abstract: Decoupling control of the air supply system is crucial for enhancing the performance and prolonging the service life of proton exchange membrane (PEM) fuel cells. However, the strong coupling and nonlinearity inherent in the system… read more here.

Keywords: air supply; system; supply system; fuel ... See more keywords

Observer-Based Composite Adaptive Type-2 Fuzzy Control for PEMFC Air Supply Systems

Sign Up to like & get
recommendations!
Published in 2022 at "IEEE Transactions on Fuzzy Systems"

DOI: 10.1109/tfuzz.2020.3041297

Abstract: Polymer electrolyte membrane fuel cell (PEMFC) air supply systems are usually affected negatively by model uncertainties, external disturbance, and unmeasured variables. In this article, we propose a composite adaptive type-2 fuzzy controller based on a… read more here.

Keywords: air supply; composite adaptive; type fuzzy; supply systems ... See more keywords

Adaptive Coordinated Control for Nonlinear PEM Fuel Cell Air Supply Systems

Sign Up to like & get
recommendations!
Published in 2025 at "IEEE Transactions on Industrial Electronics"

DOI: 10.1109/tie.2024.3468708

Abstract: Simultaneous control of the oxygen excess ratio (OER) and cathode pressure is crucial in ensuring the dynamic performance and durability of proton exchange membrane fuel cells (PEMFCs). However, it is challenging to perform coordinated multivariable… read more here.

Keywords: control; air supply; fuel; adaptive coordinated ... See more keywords

Nonlinear Observer-Based Air Supply Subsystem Control via a High-Order Fully Actuated Approach for Fuel Cell

Sign Up to like & get
recommendations!
Published in 2025 at "IEEE Transactions on Vehicular Technology"

DOI: 10.1109/tvt.2025.3580806

Abstract: In the air supply subsystem of proton exchange membrane fuel cells (PEMFCs), airflow rate and cathode pressure are key state variables and require precise coordinated control to improve the service life of the proton exchange… read more here.

Keywords: control; air supply; fully actuated; supply subsystem ... See more keywords