Articles with "amperometric detection" as a keyword



Detection of Cisplatin with Boron‐Doped Diamond Thin‐Film Electrodes Using Flow Injection Analysis and Ion Exclusion Chromatography with Amperometric Detection

Sign Up to like & get
recommendations!
Published in 2025 at "Electroanalysis"

DOI: 10.1002/elan.70007

Abstract: In this work, we investigated the electrochemical behavior of cisplatin at boron‐doped diamond (BDD) thin‐film electrodes using cyclic voltammetry. Flow injection analysis with amperometric detection (FIA‐EC) was used to determine the detection figures of merit.… read more here.

Keywords: detection; cisplatin; ion exclusion; exclusion chromatography ... See more keywords

Enhanced amperometric detection of paracetamol by immobilized cobalt ion on functionalized MWCNTs - Chitosan thin film.

Sign Up to like & get
recommendations!
Published in 2018 at "Analytical biochemistry"

DOI: 10.1016/j.ab.2018.05.004

Abstract: In the present study, a nanocomposite of f-MWCNTs-chitosan-Co was prepared by the immobilization of Co(II) on f-MWCNTs-chitosan by a self-assembly method and used for the quantitative determination of paracetamol (PR). The composite was characterized by… read more here.

Keywords: amperometric detection; paracetamol; enhanced amperometric; detection paracetamol ... See more keywords

Amperometric detection of the herbicide mesotrione based on competitive reactions at nitroreductase@layered double hydroxide bioelectrode

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Electroanalytical Chemistry"

DOI: 10.1016/j.jelechem.2019.01.054

Abstract: Abstract A mesotrione monitoring biosensor was prepared using a nitroreductase (NfrA2) immobilized on a glassy carbon electrode by adsorption on nanoparticles of Mg2Al-NO3 layered double hydroxides (MgAl-NPs). The amperometric transduction process was based on a… read more here.

Keywords: based competitive; detection herbicide; mesotrione; layered double ... See more keywords

Determination of chlorine ions in raw milk by pulsed amperometric detection in a flow injection system.

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of dairy science"

DOI: 10.3168/jds.2018-14395

Abstract: Chloride ion concentration in milk was determined by pulsed amperometric detection in a flow injection system. Results showed that the Au electrode lost 3 electrons at 1.10 V and formed chloroaurate ions (AuCl4-) by combining… read more here.

Keywords: milk; detection flow; detection; flow injection ... See more keywords